AQUA water quality measuring device COD automatic measuring device COD-3100-COD-3100
AQUA water quality measuring device COD automatic measuring device COD-3100-Anatec Yanaco Co., Ltd.

AQUA water quality measuring device COD automatic measuring device COD-3100
Anatec Yanaco Co., Ltd.


About This Product

An automated device that measures COD (Chemical Oxygen Consumption), an important parameter for knowing the water quality of river water or industrial wastewater, based on the Japanese Industrial Standard JIS K0102 (Industrial Wastewater Testing Method) and Sewage Testing Method. is. We have further evolved the COD automatic measuring device, which has a proven track record of high reliability and stability, and are now delivering the "COD-3100" as a new model that meets user needs. While retaining the same maintainability and measurement performance as before, the amount of cleaning water used has been reduced to approximately 1/20.

■Features

・Since measurements can be made under the same temperature conditions as the JIS method, the measured values ​​have a high correlation with the values ​​obtained by the specified measurement method. Additionally, controlling the heating temperature eliminates the need for cooling water, reducing tap water consumption to approximately 1/20 compared to conventional methods. ・The end point is detected using a constant voltage method and polarization potential difference method using twin platinum electrodes that can differentially detect redox reactions, allowing accurate end point detection at all times without being affected by the properties of the sample. - Samples are sampled by negative pressure suction from a sample water tank with a built-in filtration filter. In addition, by performing backflow cleaning using the sample and air, there is no sample remaining inside the piping, preventing dirt from adhering to it. Problems caused by samples containing turbidity components such as SS (flow path blockage, etc.) and maintenance are reduced, making it possible to maintain long-term performance.

■Repeatability (with standard solution)

・Full scale ±1% (for measurement range 20mg/L) ・Full scale ±2% (for measurement ranges exceeding 20mg/L and below 200mg/L) ・Full scale ±3% (when measuring range exceeds 200mg/L) *For two-step dilution measurement, full scale ±4%...Option

■Zero drift/span drift

・Both zero and span drift (in 24 hours) ・Full scale ±3% (for measurement range 20mg/L to 200mg/L or less) ・Full scale ±4% (when measuring range exceeds 200mg/L) (Full scale ±5% for two-step dilution measurement)

■Installation space

Maintenance space of 1m in front and approximately 0.6m in rear is required.

  • Product

    AQUA water quality measuring device COD automatic measuring device COD-3100

Share this product


70+ people viewing

Last viewed: 2 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

1 Models of AQUA water quality measuring device COD automatic measuring device COD-3100

Image Part Number Price (excluding tax) Power supply Piping diameter Mass Reagent replenishment Reagent consumption: Acid method (no silver nitrate added) Reagent consumption: Acid method (silver nitrate addition) Reagent consumption: alkaline method Sample conditions Installation conditions End point detection Titration method Measuring range Measurement method: Sulfuric acid acid potassium permanganate method Measurement method: Alkaline potassium permanganate method Measurement period Power consumption Number of samples Ground Dilution/washing water conditions External input/output 5 External input/output 4 External input/output 3 External input/output 2 External input/output 1 External dimensions Printing method Printed content Heating method Saved data Display
AQUA water quality measuring device COD automatic measuring device COD-3100-Part Number-COD-3100

COD-3100

Available upon quote

AC100V 50/60Hz (built-in earth leakage breaker)

Tap water inlet: Rp1/2 (valve socket nominal diameter 13A)
Drain outlet: Rp1 (valve socket nominal diameter 25A)
Sample inlet: Rc1/8 (attached union)

Approximately 145kg

Continuous measurement is possible for 14 days without reagent replenishment with a measurement cycle of 1 hour.

Potassium permanganate solution 13.5mL
Sodium oxalate solution 10mL
Sulfuric acid solution 10mL

Potassium permanganate solution 13.5mL
Sodium oxalate solution 10mL
Sulfuric acid solution 10mL
Silver sulfate solution 5mL
Ammonia water approx. 170mL

Potassium permanganate solution 13.5mL
Sodium oxalate solution 10mL
Sulfuric acid solution 10mL
Sodium hydroxide solution 10mL

Water temperature: 2~40℃
Pressure: 0.02~0.05MPa
Flow rate: 1~5L/min

Indoor installation (installed in a building as close as possible to the water sampling point, avoiding direct sunlight)
Temperature: 2~40℃
Humidity: 85%RH or less
Vibration: General factory level
Atmosphere: A place free of corrosive gases (H2S/SO2/NH3/CL2, etc.)

End point differential detection method of redox potential (galvanostatic polarization potentiometric method)

Slow injection continuous titration method using burette

Specify one range from 0~20,30,40,50,100,200,300,400mg/L (0~500mg/L or more is possible as an option)

Acidic method (no silver nitrate added): When the chloride ion concentration is low and the catalytic effect of silver salt is less affected
Acidic method (silver nitrate addition): When the chloride ion concentration of the sample (+ dilution water) is approximately 2000 mg/L or less

Alkaline method: When the chloride ion concentration of the sample (+ dilution water) is approximately 2,000 mg/L or more

Shortest measurement cycle: approximately 45 minutes
Repeat measurements, arbitrary measurements, and measurement starts using external contact signals are also possible.

Approximately 700VA (at maximum load)

1 sample (2 or more samples available as an option)

Class D grounding (separate from power grounding)
(No sudden voltage fluctuations)

Tap water or purified water (less variation in COD value)
Water temperature: 2~35℃
Pressure: 0.1~0.4MPa
Usage amount: 1.5L/measurement (for cleaning and dilution)

External start input No-voltage A contact input (1 second or more)

Maintenance contact output (MAINT.) No-voltage a contact output (contact capacity 1A or less when DC30V)

Alarm contact output No-voltage A contact output (1A or less when contact capacity is 30V DC)
Concentration upper limit alarm
Sample cutting *optional
Washing water cutoff
Instrument abnormality
End point detection
Power off

Measured value current output DC4~20mA±0.08mA (insulated) Load resistance 500Ω or less
*Equipped with 1 output as standard
Measured value output is a hold signal (until next measured value output)

Measured value voltage output DC0.000~1.000V within ±0.005V (non-insulated)

(W) 600 × (D) 600 × (H) 1,600mm (channel base type)

Graphic printer thermal paper (paper width 58mm) (automatic winding mechanism included as standard)

Setting values, measured values, manual analysis conversion values ​​(according to y=a+bx settings), measured value bar graphs, calibration values, daily reports, power off, various alarms/abnormal location individual marks printing, etc. (forward/reverse order printing selectable) )

Boiling water circulation method (oil circulation method available as an option)

Measurement data: Approximately 6 months
End point history data: about 1 month
Alarm history data: Latest 10 items

7 inch lcd display

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More COD Meters Products

Other products of Anatec Yanaco Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Anatec Yanaco Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree