■Shear viscosity × extensional viscosity.

Achieves corrected and accurate shear viscosity measurements with high reproducibility. Furthermore, the tensile viscosity can be easily measured to determine the true nature of the material. Imatec's R6000 provides a new benchmark for material design, with flexible control software and a robust frame that eliminates measurement errors, highlighting the precise information needed for molding.

■Features

- Computer-controlled twin capillary rheometer with two measuring tubes. ・No periodic calibration work by the operator is required. Automatic calibration with platinum sensor (high accuracy 0.01%, temperature stability 0.0003%/℃, temporal fluctuation rate 0.001%/year). ・The barrel is divided into 3 zones, and each zone can control the temperature independently. The temperature uniformity throughout the barrel is also outstanding. The temperature control sensor is a newly developed knuckle heater located very close to the center of the barrel. Precise control of sample temperature. - The variable range of piston speed is from 0.01mm/min to 500mm/min (maximum speed 1.000mm/min as an option). Using a 0.25mm die, the shear rate is up to 9.6×10 5/s. ・An ultra-precision pressure sensor is used to measure resin pressure, and measurement stability is excellent. The software has a pressure equilibrium point detection function that captures highly accurate pressure data in the minimum amount of time necessary. - Insert a pressure sensor into the die entrance and directly measure resin pressure. The load applied to the piston is measured using a separate load cell. ・A forced exhaust system may be installed in case toxic gas is generated during measurement. ・Interlock system against piston load and resin pressure overload. - In case of emergency, the front of the device is equipped with a door with a safety device to ensure the safety of the operator.

■RheoSolve software specifications Platform

Windows XP Pro SP2 or later

■RheoSolve software specifications Pressure sensor database

A database that registers pressure sensor information. Calibration information for each sensor is also saved. Select the sensor used for measurement from the database.

■RheoSolve software specifications Die database

A database that registers measurement die information. Select the die to be used for measurement from the database.

  • Product

    Computer-controlled twin capillary rheometer R6000

Share this product


40+ people viewing

Last viewed: 4 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

1 Models of Computer-controlled twin capillary rheometer R6000

Image Part Number Price (excluding tax) Measurement selection range Measurement Measurement accuracy Measurement temperature sensor Measurement pressure sensor Measurement Force measurement Measurement piston control range Measurement sensor connection channel Temperature control Temperature measurement accuracy Temperature control Temperature control range Temperature control temperature sensor Temperature control material Mechanism measuring barrel Mechanism structure Mechanism Required power supply Mechanism safety mechanism Mechanism External dimensions/weight Mechanism frame strength Capillary die precision Capillary die lineup RheoSolve software specifications Display/output functions RheoSolve Software Specification Recommended System RheoSolve Software Specifications Control Functions
Computer-controlled twin capillary rheometer R6000-Part Number-R6000

R6000

Available upon quote

3.5・5・7・10・20・35・50・70・100・140・200Mpa

±0.25% of measurement range

Platinum sensor (according to DIN43760)

Direct detection of pressure loss within each bore.

Transducer in crosshead (standard 50kN)

0.01mm/min~500mm/min
Drive motor encoder 10,000 (resolution: 0.02μm) Error less than 50μm for piston full travel.

5 channels, 4-20mA 16bit data conversion

Less than ±0.5℃.

Room temperature +10℃~400℃

Platinum sensor (according to DIN43760)

3-zone temperature measurement and control.

Twin bore type ◎Each φ15mm standard (optional φ12mm, φ20mm)
Bore length: 280mm (with option to tilt the barrel forward by 28° for cleaning)

Sturdy H frame structure with two φ65mm bars.

Single phase 220VAC 50/60Hz 16A

Protective screen door (interlocking)
Crosshead force transducer, motor overcurrent, emergency stop switch, exhaust mechanism compatible, machine safety standards 89/392/EEC and 91/368/EEC certified

730mm (width) x 800mm (depth) x 2,400mm (height)
Weight: 400kg

290kN

Diameter: within ±5μm
Length: Within ±10μm

Length: 0.25mm~40mm
Diameter: 0.25mm~5mm
Incident angle: 60°~180°

Graph display of shear viscosity, extensional viscosity, etc., real-time graph display of sensor detection values, list display of measurement conditions, list display of numerical data, data output in Microsoft Excel, CSV, ASCII format.

Pentium3 1GHz or higher 512MB memory 40GB hard disk
10Base T network port for connection to rheometer.

Crosshead control, temperature control (3 zone division), measurement condition setting (temperature equilibrium and pressure value)

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Capillary Rheometers Products

Other products of ITS Japan Co., Ltd.

Reviews shown here are reviews of companies.


View more products of ITS Japan Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree