Product
AC DC open frame low profile LOP-200 for multi-field applicationsHandling Company
FranMar International Inc.Categories
Product Image | Part Number | Price (excluding tax) | AC current (typical) | AC input voltage range | EMC standard | Frequency range | Holdup time (typical value) | Inrush current (typical value) | Line regulation | Load regulation | Overheating protection | Overload protection | Overvoltage protection | Packing | Power factor | Rated power convection | Rated power with fan cooling | Safety standards | Setup, rise time | Size | Working temperature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
LOP-200-12 |
Available upon quote | 2.5A/115VAC 1.0A/230VAC | 80~264VAC; DC113~370V | EN55032 Class A and B, BS EN/EN55035, BS EN/EN61000-6-2, EN61000-3-2, 3, EN61000-4, 2, 3, 4, 5, 6, 8, 11 | 47~63Hz | 16ms@140W load, 8ms@200W load | Cold start 40A/115VAC 80A/230VAC | ±0.5% | ±1.0% | Type: Shut down O/P voltage and automatically recover after temperature rise (3 seconds) or recover after power cycle | Range: 105%~135% rated output power; Type: Hiccups after 3 seconds, automatically recovers when the fault condition is cleared (3 seconds) | Type: Shut down O/P voltage and power cycle to recover | 210g, 36 pieces/10kg/0.95CUFT | At full load PF>0.95/230VAC PF>0.98/115VAC | 140.4~145.8W | 199.8~205.2W | IEC/EN/UL62368-1, IEC/EN/BS EN60335-1, IEC/EN/BS EN61558-1, IEC/EN60601-1, CCC, RCM, EAC TPTC 004 | 1000ms, 30ms/AC230V at full load 1500ms, 30ms/AC115V | L101.6×W50.8×H25.4mm | -40℃~+80℃ (see output derating curve) |