Product
Thermo-paramagnetic oxygen concentration meter XTP601 for hazardous areasHandling Company
PST Japan Co., Ltd.Categories
Image | Part Number | Price (excluding tax) | Electrical specifications Power supply | Electrical specifications Output range | Electrical specifications Data logging | Electrical specifications Digital communications | Electrical specifications Cable connection | Electrical specifications Alarm | Electrical specifications Analog input | Weight | Size | Stability time | Operating conditions Atmospheric pressure | Operating conditions Ambient temperature | Specifications Display resolution | Specifications Accuracy (excluding zero range) | Specifications Linearity | Specifications Measuring range | Specifications Measurement technology | Specifications Response time (T90) | Specifications Reproducibility | Specifications Background gas | Specifications Display type | Specifications Accuracy excluding zero range (80/90-100%) | Specifications Zero stability | Specifications Span stability | Specifications Sample temperature | Specifications Sample flow rate | Specifications Sample pressure | Specifications Sample cell temperature | Specifications gas | Warm up time |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
XTP601 |
Available upon quote |
24VDC; 1.5A max |
1ch: Set to device calibration range |
Record output via digital communication |
Modbus RTU with RS485 protocol |
3 x M20 cable |
X2, single pole switching (SPCO) relay for O2 concentration |
X2, 4-20mA |
9.7kg |
234×234×172mm (width x depth x height) |
5 minutes |
750mbar~1,250mbar |
+5~+55℃ |
0.01% from zero range |
<±1% of span or ±0.02%O2, whichever is greater |
±0.5% of span or 0.05%O2, whichever is greater |
Selectable from 0~0.5%, 0~50%, 20/80/90~100% |
Thermo-paramagnetic type |
<15 seconds *Enable (HSR) with high speed response |
±0.2% of span or 0.01%O2, whichever is greater |
The analyzer is calibrated with process background gas. |
LCD with backlight |
<0.2% O2 |
±0.25%/month of span |
±0.25%/month of span |
5~+55℃ MAX |
GP1, GP3: 100~500ml/min |
0~3barag (0-300kPa) Open to atmosphere |
Standard: +50℃, |
Process, non-condensed sample particles <3μm |
<25 minutes |