Thermo-paramagnetic oxygen concentration meter XTP501Handling Company
PST Japan Co., Ltd.Categories
Image | Part Number | Price (excluding tax) | Power supply | Weight | Startup time | Alarm | Fitting | Size | Stability time | Operating conditions Ambient temperature | Output range | Mechanical specifications linearity | Mechanical specifications Measuring range | Mechanical specifications Measurement principle | Mechanical specifications Measuring gas | Mechanical specifications Intrinsic errors (accuracy) | Mechanical specifications Reproducibility | Mechanical specifications Background gas | Mechanical specifications Display resolution | Mechanical specifications display | Mechanical specifications Zero stability | Mechanical specifications Span stability | Mechanical specifications Sample flow rate (general purpose) | Mechanical specifications Sample cell temperature | Mechanical specifications Gas requirements | Data logging | Digital communication | Gas connection | Analog output | Analog input | O-ring material | IP protection requirements |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
XTP501 |
Available upon quote |
24VDC; 1.5A max |
Approximately 3kg |
<25 minutes (@environment temperature 20℃) |
Two off single-pole switching relays for centralization (250 V, max. 5 A) |
316SUS, borosilicate glass, platinum, and O-rings |
260 x 180 x 128mm |
5 minutes |
+5~+40℃ |
The main range is set to the instrument's calibration range, sub-ranges are user selectable. |
±0.5% of span or 0.05% O2, whichever is greater |
It will be adjusted according to the customer's request range. Selection range: 0~0.5%, 0~50%, 20, 80 or 90~100% |
Thermoparamagnetic oxygen sensor |
Oxygen |
<±1% of span, ±0.02%O2, whichever is greater |
±0.2% of span or 0.02% O2, whichever is greater |
The analyzer is calibrated on the background gas of the process. |
0.01% 0.1% for zero negative transition range |
LCD with backlight *Excluding XTP501GP2 model |
±0.25% of span/1 month |
±0.25% of span/1 month |
5~60℃ (constant temperature) |
+50℃ |
Non-condensed samples with particles less than 3 μm |
Output from the analyzer can be logged to an external device using digital communications |
Modbus RTU RS485 protocol communication |
1/8" bulkhead standard |
X2 4-20 mA output (power supply: excitation voltage 24V) |
X1 mA input for external sensor (can be displayed on screen) |
Byton |
IP55 |