Product
Online hydrocarbon dew point analyzer Condumax ⅡHandling Company
PST Japan Co., Ltd.Categories
Image | Part Number | Price (excluding tax) | Certification Explosion proof certification | Hydrocarbon dew point measurement resolution | Hydrocarbon dew point measurement accuracy | Hydrocarbon dew point measurement Measurement frequency | Hydrocarbon dew point measurement measurement technology | Hydrocarbon dew point measurement maximum range | Hydrocarbon dew point measurement Operating pressure | Hydrocarbon dew point measurement Sensor cooling | Hydrocarbon dew point measurement Sample flow rate | Hydrocarbon and water dew point temperature measurement Power supply | Hydrocarbon and water dew point temperature measurement Weight | Hydrocarbon and water dew point temperature measurement Operating environment | Hydrocarbon and water dew point temperature measurement Sample gas supply | Hydrocarbon and water dew point temperature measurements Gas connections | Water dew point measurement selection unit | Water dew point measurement resolution | Water dew point measurement accuracy | Water dew point measurement range | Water dew point measurement measurement technology | Water dew point measurement Operating pressure | Pressure measurement Pressure resolution in hydrocarbon dew point analysis | Pressure Measurement Pressure Accuracy in Hydrocarbon Dew Point Analysis | Pressure measurement Pressure units for hydrocarbon dew point analysis |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Condumax II |
Available upon quote |
ATEX:II 2G Ex d e IIB+H2 T3 Gb |
0.1℃ |
Hydrocarbon dew point ±0.5℃ |
6 cycles/hour (recommended) |
Dark spot fixed sample analysis |
Maximum Δ55℃ from the operating temperature of the main unit |
Up to 100 barg |
Automatic 3-stage Peltier cooling system |
0.03 ~ 0.06 m3/hr |
110 or 230VAC, 50/60Hz, 300W |
Approximately 60kg |
Indoor/outdoor 0~40℃; max. 95%RH |
Natural gas: up to 100 barg |
Sample inlet, filter bypass outlet, system drain. |
Dew point:℃ water dew point |
0.1℃dp |
±1℃:-59~+20℃dp |
Calibration range: -100~ +20℃dp |
Michel Metal Oxide (Aluminum Oxide) Moisture Sensor |
Max. 138 barg (2,000 psig) |
0.1 MPa and barg, 1 psig |
Hydrocarbon dew point ±0.25 barg |
MPa, barg, psig |