A new image processing algorithm enables stable reading without being affected by scratches, etching, changes in brightness, etc. In order to detect the reflectance of the sample surface with high precision, readings are made that follow changes in brightness.

■Function

-Automatic reading and autofocus functions eliminate individual errors caused by visual inspection and contribute to reducing fatigue of the measurer. There is no need for education on ensuring measurement reproducibility at the individual level. ・Reading repeatability/±0.5% (test force 9807mN, 700HV, objective lens x 40) ・Significant reduction in measurement costs/Reading speed: 0.5 seconds/1 point, autofocus speed: 3 seconds/1 point (varies depending on sample surface conditions) ・Various measurement functions allow measurements to be performed under various conditions. - In addition to a wide variety of pattern functions, the coordinate rotation mechanism allows you to create measurement patterns that match the inclination of the sample end face, and the trace function allows you to create copy patterns.

  • Product

    Semi-automatic hardness testing system AMT/AVT-PS series

Share this product


40+ people viewing


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

1 Models of Semi-automatic hardness testing system AMT/AVT-PS series

Image Part Number Price (excluding tax) Automatic reading function Minimum recess that can be read Automatic reading function Test mode Automatic reading function Test data retention format Automatic reading function test scale Automatic reading function Measuring field of view Automatic reading function Display magnification Automatic reading function Minimum measurement unit Automatic reading function Manual depression measurement Automatic reading function Supported languages Automatic reading function Compatible OS Automatic reading function Print output Automatic reading function Graph display Automatic reading function Others Automatic reading function Hollow reading speed Automatic reading function Hollow reading reproducibility Automatic reading function CCD camera Automatic X-Y axis stage Other functions Automatic X-Y stage drive method Automatic X-Y stage test score Automatic X-Y stage movement amount Automatic X-Y stage movement program pattern Automatic X-Y stage movement speed Automatic X-Y stage Stage dimensions Automatic X-Y stage Stage operation Minimum movement unit automatic X-Y stage
Semi-automatic hardness testing system AMT/AVT-PS series-Part Number-PS series

PS series

Available upon quote

20μm (at 400x objective lens)

Single mode (indentation dot and indentation reading for each point)

Dedicated format/XLS format

Vickers hardness (HV), Knoop hardness (HK), fracture toughness (KC) (manual measurement only), cylinder correction (optional)

Approximately 70μm (40x objective lens, approximately 140μm (20x objective lens), approximately 280μm (10x objective lens), approximately 560μm (5x objective lens)
For AVT/PVT series, the field of view is approximately twice as large.

Approximately 1,600x (when objective lens is 40x), approximately 800x (when objective lens is 20x), approximately 400x (when objective lens is 10x), approximately 200x (when objective lens is 5x)
For AVT/PVT series, the magnification is approximately half that.

0.1μm

Manual measurement on a PC monitor using a mouse, visual measurement using a measuring microscope (optional) - Visual measurement data transfer function to PC (optional)

Japanese/English

Windows 10 compatible

Three standard format selections (graph only, data only, graph & data)
Supports dedicated format (optional)

Hardened layer depth, maximum value, minimum value, X and Y axis independent distance display, parameter settings

Judgment function/reading option function based on diagonal length ratio (Easily select from 4 arbitrarily set automatic reading settings)

Minimum 0.5 seconds/1 point (varies depending on sample surface)

±0.5% (Test force: 9807mN, 700HV, with 40x objective lens)

1/2 inch 1.3M monochrome USB camera
(You can change to your desired pixel in the option)

Real-time graphic display of test position, click movement function, dry run function, stage offset function for indentation point position when changing indenter

Stepper motor

Up to 198,000 points can be set (up to 2,000 points per line, maximum 99 lines can be set)

X/Y each 50×50mm
Can be changed to desired travel amount (optional)

Straight line (start point/end point specification, pitch specification, pitch variable specification), arc, circle, teaching, tracing, coordinate rotation, shape recognition (shape copying, line origin setting)

0.05~5mm/sec Can be changed arbitrarily within the range shown on the left

X・Y each 110×110mm
Can be changed to desired size (optional)

Stage control box operation (optional speed change possible)
Icon operation on software (2 speeds can be changed)

1μm

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Positioning Stages Products

Other products of Matsuzawa Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Matsuzawa Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

14.2hrs

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree