All Categories
History
Product
Emergency power switchboard (for both indoor and outdoor use) to quickly restore power to important infrastructure equipment such as disaster prevention administrative radio systems and road information display boards, as well as wireless relay stations aHandling Company
Morinaga Electronics Co., Ltd.Categories
Image | Part Number | Price (excluding tax) | Voltage drop in lightning protection unit for power supply | Lightning protection unit for power supply Applicable line | Power supply lightning protection unit test class | Power supply lightning protection unit residual surge energy | Power supply lightning protection unit maximum discharge current | Lightning protection unit for power supply method | Power supply lightning protection unit operation speed | Power supply lightning protection unit separator | Lightning protection unit for power supply Usage environment | Lightning arrester unit for power supply Surge energy attenuation amount | Automatic reset breaker section Automatic reset time | Automatic reset breaker section power consumption | Automatic return breaker section Permanent cutoff judgment time | Automatic return breaker section rated current | Automatic reset breaker section rated voltage | Automatic reset breaker section Rated earth leakage sensitivity current | Automatic return breaker section operation count | Automatic return breaker section Lightning resistance of control circuit | Automatic return breaker section Usage environment | Dielectric strength | Insulation resistance | Rated voltage/current | Commercial and emergency power switching section Emergency power input cable | Commercial and emergency power switching section Number of poles | Commercial and emergency power switching section Rated current | Commercial and emergency power switching section Switching method | Box structure | Box part material | Box part type | Box part dimensions |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SEP-E10-R |
Available upon quote |
0.5V or less |
1φ2W, AC100V, 10A |
Class II and Class III |
3mJ or less (at nominal discharge current) |
20kA/40kA (at 8/20μs) |
Surge energy attenuation method |
3nsec. or less |
Built-in |
Temperature: -40~70℃ |
-58dB or more (at nominal discharge current) |
5 seconds, 10 seconds, 30 seconds, 60 seconds, 5 minutes, 10 minutes, 30 minutes, 60 minutes (default setting is 5 seconds) |
Standby: 3.0VA or less, 30mA or less |
When tripped again within 3 seconds after turning on |
10A (30AF) |
1φ2W, AC100V±10% (50/60Hz) |
30mA |
Counts and displays the number of operations up to 9 times |
30kV to ground (at 1.2/50μs) |
Temperature: -10~50℃ |
AC2,000V, 1 minute |
50MΩ or more at DC500V |
1Φ2W, AC100V, 10A |
5m (with outlet) |
2 poles |
30A |
Manual |
Munsell 5Y7/1 |
Glass fiber reinforced polycarbonate resin |
Outdoor wall-mounted type |
W366×H546×D163 (mm) |