Product Image | Part Number | Price (excluding tax) | Appearance/Structure | Appearance/Structure Dimensions | Appearance/Structure Lightning surge protection | Appearance/Structure Material | Appearance/Structure Paint color | Automatic reset breaker section Automatic reset time | Automatic reset breaker section Rated earth leakage sensitivity current | Automatic reset breaker section power consumption | Automatic reset breaker section rated voltage | Automatic return breaker section Lightning resistance of control circuit | Automatic return breaker section Permanent cutoff judgment time | Automatic return breaker section Usage environment | Automatic return breaker section operation count | Automatic return breaker section rated current | Commercial and emergency power switching section Emergency power input cable | Commercial and emergency power switching section Number of poles | Commercial and emergency power switching section Rated current | Commercial and emergency power switching section Switching method | Dielectric strength | Insulation resistance | Lightning arrester unit for power supply Surge energy attenuation amount | Lightning protection unit for power supply Applicable line | Lightning protection unit for power supply method | Power supply lightning protection unit maximum discharge current | Power supply lightning protection unit operation speed | Power supply lightning protection unit residual surge energy | Power supply lightning protection unit separator | Power supply lightning protection unit test class | Rated voltage/current | Voltage drop in lightning protection unit for power supply |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SEP-E10 |
Available upon quote | Outdoor wall-mounted type | W400×H530×D200 (mm) |
Voltage surge 1.2/50μs, current surge 8/20μs There should be no functional abnormality when applying the combination waveform. |
SUS304t1.5 | Munsell 5Y7/1 | 5 seconds, 10 seconds, 30 seconds, 60 seconds, 5 minutes, 10 minutes, 30 minutes, 60 minutes (default setting is 5 seconds) | 30mA |
Standby: 3.0VA or less, 30mA or less When driving solenoid: 130VA, 1.3A or less |
1φ2W, AC100V±10% (50/60Hz) | 30kV to ground (at 1.2/50μs) |
When tripped again within 3 seconds after turning on When tripped 8 times within 8 hours |
Temperature: -10~50℃ | Counts and displays the number of operations up to 9 times | 10A (30AF) | 5m (with outlet) | 2 poles | 30A | Manual |
AC2,000V, 1 minute (However, excluding the lightning protection unit part) |
50MΩ or more at DC500V (However, excluding the lightning protection unit part) |
-58dB or more (at nominal discharge current) | 1φ2W, AC100V, 10A | Surge energy attenuation method | 20kA/40kA (at 8/20μs) | 3nsec. or less | 3mJ or less (at nominal discharge current) | Built-in | Class II and Class III | 1Φ2W, AC100V, 10A | 0.5V or less |