This product is registered by Seiwa Disaster Prevention Co., Ltd..
About This Product
■Product overview
- Manufactured based on the concept of "a compact electric lock control device equipped with the functions necessary for normal operation."
・A/B/E 3-mode operation is possible, centering on MIWA/GOAL electric lock control.
- Compatible with the mainstream JEM-A standard control via intercom, so locking/unlocking can be controlled directly from the JEM-A control device.
- Since this is a board type that is not installed in an outer box, it is assumed that it will be installed concealed inside a storage panel or wall, or installed on other equipment.
Features
■Electric lock control 3 patterns of control input
1.1Shot make control input (for non-voltage contact)
By operating in A/B/E mode, unlocking and locking operations can be performed in accordance with the system.
2.Continuous unlocking input (for non-voltage contact)
It is possible to forcibly hold the lock unlocked. The contacts remain unlocked during make.
3.JEM-A standard control (HA terminal)
This unit can be operated from a JEM-A control device such as an intercom. This is the same control as the 1Shot control input in item 1 above.
■Electric lock control in A/B/E modes
・A mode: Automatically locks the door
・B mode: Lock/unlock repeatedly
・E mode: Combined use of A mode (operating with this unit) and B mode (manual operation)
*E mode can only be operated normally with compatible electric locks.
Other features
■Temporary unlock timer
After unlocking, you can select the number of seconds you want to wait until the electric lock automatically locks if it is not activated.
■Door over-opening error
If the door remains open for more than the set number of seconds, it will be recognized as an abnormality.
■Electric lock abnormality notification
If there is an abnormality in the electric lock operation, a signal will be output from the abnormality alarm output terminal to notify you of the abnormality. The LED on the board flashes in a lighting pattern depending on the error content.
■Remarks About JEM-A standard (HA terminal)
・This product is designed, manufactured and tested in accordance with JEM-A standards.
・Therefore, we have confirmed normal operation at the specified connection distance of 1.9m with the JEM-A interface device.
・If you connect and use the product at a distance greater than that, please thoroughly check the operation.
・Please note that operation is not guaranteed if the distance between the JEM-A terminals is 1.9m or more.
This is the version of our website addressed to speakers of English in