All Categories

History

Ultrasonic flow meter for chemical liquids and pure water USF500N/600N/560N Series-USF500N-G08
Ultrasonic flow meter for chemical liquids and pure water USF500N/600N/560N Series-Toflo Corporation Co., Ltd.

Ultrasonic flow meter for chemical liquids and pure water USF500N/600N/560N Series
Toflo Corporation Co., Ltd.


About This Product

■Features

- Equipped with DSP function to improve stability, responsiveness, and bubble resistance. ・Achieves space saving by adopting 2 channels. - Detachable cable makes wiring work easy. ・Can handle high temperature fluids. (Max.200℃, high temperature specification) ・Multi communication. (Up to 31 units can be connected)

  • Product

    Ultrasonic flow meter for chemical liquids and pure water USF500N/600N/560N Series

Share this product


10+ people viewing

Last viewed: 1 hour ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

1 Models of Ultrasonic flow meter for chemical liquids and pure water USF500N/600N/560N Series

Image Part Number Price (excluding tax) Power supply voltage Communication function Measurement method Number of measurement channels Burst pressure 200℃ (180℃, 90℃) Measured flow rate accuracy (at time of shipping calibration) Measurement flow range Current consumption Fluid Detector Wetted parts material Detector cable length Maximum fluid temperature Maximum working pressure Minimum flow rate Connection diameter Input signal (digital input) contact Operating environment temperature Data update cycle Digital output Accumulated pulse output (accumulated flow rate) Digital output Instantaneous frequency output (instantaneous flow rate) Digital output Comparison output Digital output output rating Digital output Error output Analog output Measurement output DC4-20mA
Ultrasonic flow meter for chemical liquids and pure water USF500N/600N/560N Series-Part Number-USF500N-G08

USF500N-G08

Available upon quote

DC24V±10%

RS-485 (Modbus-RTU/USF protocol) Up to 31 converters can be connected
Communication speed: 9,600, 19,200, 38,400, 57,600bps

Ultrasonic propagation time difference method

2 channels

0.98MPa (G)
This is the standard value obtained by multiplying the burst pressure at room temperature by the burst pressure reduction coefficient of 200℃ (G08: 180℃). When using it, we recommend operating it at 1/2 to 1/5 of the standard value.

±1% of R.D. *Less than 10% of the measured flow rate range: ±0.1% of F.S.
"Instantaneous flow rate accuracy calibrated with pure water at 20°C (room temperature at 25°C) and stable flow rate.

0~3L/min

Normal: 170mA or less (rush current: approx. 9A / 0.5ms or less)

Pure water, slurry, chemical solution (IPA, H₂O₂, H₂SO₄, H₃PO₄, HF, HCl, O₃, NH₃, etc.)

NEW PFA

Standard cable (PVC coated): 3,000mm (allowable bending radius: approx. 11mm)
ETFE cable (ETFE coated): 3,000mm (allowable bending radius: approx. 15mm)

Standard: 90℃
High temperature: 180℃ *USF600 type is not supported.

Below 90℃: 0.5MPa (G)
90~200℃ (or 90~180℃):0.2MPa (G) *USF600 type is not supported.

Standard 0.001L/min

Tube end 1/4″ (φ6.35×4.35)

TTL or no-voltage contact input
2 input ports, only 1 type of input per system can be reset
Select from integrated value reset input and zero point adjustment input for each CH

0~80℃ (Detector) / 0~50℃ (Converter) No condensation

10ms

Pulse flow rate setting: Accumulated flow rate per pulse can be set arbitrarily Setting range 0.001~32.000L (Setting step 0.001L)
Pulse width setting: 1~800ms (setting step 1ms)

Possible output frequency: 10~3,000Hz (F.S. frequency can be set arbitrarily in the range of 500~3,000Hz)
Possible output flow rate: χ~F.S. flow rate *Offset by χ=F.S. flow rate

Output setting: Select from instantaneous flow rate, integrated flow rate, upper limit output, and lower limit output
Comparison value setting: Instantaneous flow rate L/min/integrated flow rate L Setting range 0~32.000 (Setting step 0.001)

Applied voltage: Max. 35V (VoL=1.3V)
Sink current: Max. 100mA
Output port: 2 lines
Select from instantaneous frequency output, integrated pulse output, 4 types of comparison output, and error output for each CH

Output ON when measurement error occurs

Resolution: 12bit
Accuracy: 4mA ±0.05mA, 20mA ±0.1mA
Output port: 2 lines
Instantaneous flow range: Same as measured flow range
Accumulated flow range: Can be set arbitrarily ~32.000L

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Ultrasonic Flowmeters Products

Other products of Toflo Corporation Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Toflo Corporation Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree