Ultrasonic flow meter USF500S for chemical liquids and pure waterHandling Company
Toflo Corporation Co., Ltd.Categories
Image | Part Number | Price (excluding tax) | Power supply voltage | Communication function | Measurement method | Number of measurement channels | Burst pressure 200℃ (180℃) | Measured flow rate accuracy (at time of shipping calibration) | Measurement flow range | Current consumption | Fluid | Standard setting Digital output 2 | Standard setting Digital output 1 | Standard setting Digital input 2 | Standard setting Digital input 1 | Standard setting Analog output | Detector | Maximum fluid temperature | Maximum working pressure | Minimum flow rate | Connection diameter | Output signal Digital output Accumulated pulse output | Output signal Digital output Instantaneous frequency output | Output signal Digital output Comparison output | Output signal Digital output Output rating | Output signal Digital output Error output | Output signal Analog output Measurement output 4-20mA | Input signal (digital input) contact | Operating environment temperature | Data update cycle |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
USF500S-G08 |
Available upon quote |
DC24V±10% |
RS-485 (Modbus-RTU) Up to 31 converters can be connected |
Ultrasonic propagation time difference method |
1 channel |
The standard value is the burst pressure at room temperature multiplied by the burst pressure reduction coefficient at 200℃ (180℃). When using it, we recommend operating it at 1/2 to 1/5 of the standard value. |
±1% of R.D. * 10% or less of the measured flow rate range: ±0.1% of F.S. |
0~3L/min |
Normal: 100mA or less (rush current: approx. 8A / 0.5ms or less) |
Pure water, slurry, chemical solution (IPA, H₂O₂, H₂SO₄, H₃PO₄, HF, HCl, O₃, NH₃, etc.) |
Error output |
Instantaneous frequency output |
Total value reset |
Zero point adjustment |
Instantaneous flow rate |
Wetted parts material: NEW PFA |
Standard: 90℃ |
Below 90℃: 0.5MPa (G) |
Standard Std. 0.001L/min |
Tube end 1/4″ (φ6.35×4.35) |
Pulse flow rate setting: The integrated flow rate per pulse can be set arbitrarily. |
Possible output frequency: 10~3000Hz (F.S. frequency can be set arbitrarily in the range of 100~3,000Hz) |
Output setting: Select from instantaneous flow rate, integrated flow rate, upper limit output, and lower limit output |
Applied voltage: Max. 35V (VoL=1.3V) |
Output ON when measurement error occurs |
Resolution: 12bit |
TTL or no-voltage contact input/2 input ports/Digital input 1: Zero point adjustment input Digital input 2: Accumulated value reset input |
0~80℃ (Detector) / 0~50℃ (Converter) No condensation |
10ms |