All Categories
History
Product
Flow controller for chemical liquids and pure water FLC-US40Handling Company
Toflo Corporation Co., Ltd.Categories
Image | Part Number | Price (excluding tax) | Specifications | Specifications Accuracy Flow rate accuracy | Specifications Accuracy Stability | Specifications Accuracy Control accuracy | Specifications Accuracy Repeatability | Specifications Viscosity | Specifications Specific gravity | Specifications Port size | Specifications Required differential pressure | Specifications Model | Specifications Product name | Specifications Power part | Specifications Control flow range (mL/min) | Specifications Control pressure range | Specifications Fluid temperature | Specifications Fluid used | Specifications Orifice diameter | Specifications Analog input/output | LED specifications Normal time | LED specifications Warning Flowmeter measurement error | LED specifications Warning Flowmeter zero error | LED specifications Warning Low pressure warning | LED specifications warning Valve life warning | LED specifications Zero point adjustment | LED specification error Flow rate sensor error | LED specification error Indicated flow rate input error | LED specification error Internal memory error | LED specification error Position sensor error | LED specification error Motor operation error | LED specifications Error Error handling operation |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FLC-US40 G08 |
Available upon quote |
0.5MPa (G) |
R.D. ±1% *10~100% of full scale (minimum guaranteed value: G08 2mL/min, G10 4mL/min) |
R.D.±2% *20% or less of control range F.S.: ±0.4% of F.S. (However, minimum guaranteed value: G08 1mL/min, G10 2mL/min) |
R.D.±1% *Less than 20% of control range F.S.: ±0.2% of F.S. (However, minimum guaranteed value: G08 1mL/min, G10 2mL/min) |
R.D.±1% (minimum guaranteed value: G08 1mL/min, G10 2mL/min) |
1.0mPa・s (separate discussion) |
1 |
TUBE 1/4″ (φ6.35×4.35) |
0.05MPa, 0.1MPa, 0.15MPa |
G08, G10 |
Flow controller |
Stepper motor |
5~300, 25~500, 50~1,000, 100~2,000 |
0.05~0.3MPa (G), 0.1~0.3MPa (G), 0.15~0.3MPa (G) |
10~90℃ *No condensation. (The maximum pressure varies depending on the operating temperature.) |
DIW/chemical solution (separate discussion) |
Φ3, φ5 |
4mA: 0mL/min, 20mA: Maximum value of control flow range |
Control ON: Green light on |
Flow meter measurement error: yellow flash twice |
Flowmeter zero monitoring function ON: Orange lights up |
Lack of pressure: Yellow lights up |
Life warning: Orange flash twice |
Zero point adjustment in progress: Blue flashing |
Flow meter error: Purple 2 flashes |
Command input not connected: Red flashes twice |
System stopped: Red on |
Position sensor disconnection: Pink lighting |
Motor operation error: Purple lights up |
Abnormality detection time timeout: Pink On/Off (1 second interval) |
Reviews shown here are reviews of companies.