All Categories

History

Wave type switch illuminated type SC-Series FASTON TYPE-SC-WL01A-XXXX
Wave type switch illuminated type SC-Series FASTON TYPE-Echo Electronics Co., Ltd.

Wave type switch illuminated type SC-Series FASTON TYPE
Echo Electronics Co., Ltd.


About This Product

■Rating

5A 125V/3A 250V UL.CSA

■Contact resistance

20mΩ or less

■Insulation resistance

500MΩ or more at DC500V

■Withstand voltage

No abnormality for 1 minute at AC2,000V

■Operating temperature range

-10~+85℃ (Storage temperature -25~85℃) Name of parts used

■Case

Material Polyamide resin

■Illuminated knob

Material PBT resin

■Movable plate

・Material: Copper alloy ・Processing Ag plating

■Common terminal

・Material: Copper alloy ・Processing Ag plating

■Fixed terminal

・Material: Copper alloy ・Processing Ag plating

■Contact

Material Ag alloy, pedestal Cu

■Compression coil spring

Material piano wire

■Steel ball

Material Steel ball

■LED terminal

・Material: Copper alloy ・Processing tin plating

■LED holder

Material PBT resin

■Lens

Material: Methacrylic resin Soldering work should be done within 3 seconds using a 40W soldering iron at a temperature of 300°C to 350°C. Please solder the LED part using a 30W soldering iron at a temperature of 260°C for less than 3 seconds.

■Electrical durability

・Contact resistance 100mΩ or less ・Insulation resistance 50MΩ or more ・Withstand voltage AC1000V for 1 minute ・Operating force Same as the operating force section. ・Temperature rise: 30℃ or less, no electrical or mechanical abnormalities

■How to calculate protective resistance

Substitute the values ​​of VF (forward voltage) and IFM (forward current) in the rating table into the formula below to determine the protective resistance value.

■DC current

R=Es-VF/IF

■Alternating current

- In the case of AC power supply, connect a reverse voltage blocking diode in antiparallel to the LED. - When using a 100V AC power source, use a blocking diode with a withstand voltage of 250V or more in the reverse direction. ・The method for calculating the protective resistance is the same as for DC, but Es should be the peak voltage. (Example: AC141V for AC100V) ・Please pay attention to the resistance wattage. For AC100V, we recommend 5w or more.

  • Product

    Wave type switch illuminated type SC-Series FASTON TYPE

Share this product


80+ people viewing

Last viewed: 55 minutes ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

1 Models of Wave type switch illuminated type SC-Series FASTON TYPE

Image Part Number Price (excluding tax) Withstand voltage Impact resistance Heat resistance Moisture resistance Vibration resistance Cold resistance Insulation resistance Terminal strength (power supply contact terminal) Terminal strength (LED terminal) Temperature humidity cycle Operation unit strength Contact resistance Name of parts used Actuation force Solder heat resistance Solderability LED forward current LED forward voltage LED color LED maximum reverse voltage LED maximum operating current LED operating temperature range
Wave type switch illuminated type SC-Series FASTON TYPE-Part Number-SC-WL01A-XXXX

SC-WL01A-XXXX

Available upon quote

No dielectric breakdown

There is no abnormality in appearance or structure, and the contact resistance, insulation resistance, withstand voltage, and operating force terms are satisfied.

Insulation resistance 10MΩ or more, same as contact resistance, withstand voltage, and operating force terms

Insulation resistance 10MΩ or more, same as contact resistance, withstand voltage, and operating force terms

There is no abnormality in appearance or structure, and the contact resistance, insulation resistance, withstand voltage, and operating force terms are satisfied.

Insulation resistance 10MΩ or more, same as contact resistance, withstand voltage, and operating force terms

500MΩ or more

Satisfies electrical performance, with no terminal damage or significant play.

Satisfy electrical performance

Insulation resistance 10MΩ or more, same as contact resistance, withstand voltage, and operating force terms

The operating force and electrical performance must be satisfied, and there should be no significant play or bending in the operating section.

Less than 20mΩ per measurement

LED

500±200gf

Satisfy electrical performance without deformation of appearance or significant play in terminals.

More than 75% of the solder immersion area must be wet.

20mA/20mA/25mA

1.7V/3.5V/2.0V

Red/green/orange

4V/5V/5V

40mA/100mA/60mA

-30~85℃

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Rocker Switches Products

Other products of Echo Electronics Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Echo Electronics Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2025 Metoree