All Categories
History
Product
Digital distortion meter DTM4137Handling Company
Japan INSDAC Co., Ltd.Image | Part Number | Price (excluding tax) | Weight | Distortion measurement display accuracy (dB) | Distortion measurement display accuracy (%) | Strain measurement accuracy | Distortion measurement fundamental frequency range | Distortion measurement input level | Distortion measurement input impedance | Size | Input voltage | SINAD measurement measurement range | SINAD measurement frequency range | S/N measurement measurement range | S/N measurement frequency range | AC voltage measurement Voltage range | AC voltage measurement frequency range |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
DTM4137 |
Available upon quote |
Approximately 5kg |
0.01dB |
10%~100%: 0.1%, 1%~9.99%: 0.01%, 0.1%~0.099%: 0.001%, ≤0.1%: 0.0001% |
20Hz~20kHz: ±0.5dB, 10kHz~150kHz: ±1dB, Distortion less than 0.03%: ±2dB |
Unbalance: 10Hz~150kHz |
50mV~300V |
100kΩ//100pF |
Approximately 350 (W) × 120 (H) × 340 (D) mm |
100VAC 50/60Hz |
0dB~80dB |
10Hz~150kHz (unbalanced), 10Hz~100kHz (balanced) |
0~99.99dB |
10Hz~750kHz |
300μV~300V |
10Hz~750kHz (unbalanced), 10Hz~300kHz (balanced) |
Reviews shown here are reviews of companies.