Product
Woody biomass boiler UTSR visioHandling Company
Tomoe Shokai Co., Ltd.Categories
Product Image | Part Number | Price (excluding tax) | Ash generation amount U=100 Lit/h | Body weight ton | Boiler body dimensions (depth) Lmm | Boiler body dimensions (width) Bmm | Boiler can capacity Lit | Boiler electric capacity kW | Boiler minimum output kW | Boiler minimum output kcal/h | Boiler pressure Pa | Boiler rated input kW | Boiler rated input kcal/h | Boiler rated output kW | Boiler rated output kcal/h | Combustion air volume U=100 m3N/s | Combustion control method | Exhaust gas amount U=100 m3N/h | Flue connection diameter mm | Fuel consumption (U=100%) kg/h | Fuel consumption (U=100%) m3/h | Heat transfer area m2 | Main body drain pipe connection port | Main body return connection hole DIN | Make-up water/fire extinguishing water connection port | Maximum/minimum operating temperature ℃ | Notification related | Open tank capacity Lit | Overflow pipe connection diameter | Packing/operating weight ton | Power specifications | Power transformer capacity KVA |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
UTSR-180.32-1 |
Available upon quote | 0.47 | 5.5 | 3,385 | 1,360 | 710 | 10.3 | 54 | 46,440 |
Can body test pressure: 0.6MPa System maximum working pressure: 0.5MPa |
225 | 193,500 | 180 | 154,800 | 0.17 | Proportional ON-OFF control/30%~100% | 735 | 200 | 117.2 | 0.451 | 17 | 25A | 65AF |
Manual water supply/20A Automatic water supply/15A Fire extinguishing water/20A |
80℃/60℃ Note: Please consult us for temperatures above 80℃. |
Fire Service Act/Air Pollution Control Act | 83 | 50A | 5.48/6.49 |
Power supply 200V 50/60Hz 3 phase Boiler power supply 230V 50/60Hz 3 phase |
15 |