All Categories

History

Latent heat recovery type non-pressure water heater TSiFTα BHC-800 series-BHC-825
Latent heat recovery type non-pressure water heater TSiFTα BHC-800 series-Tomoe Shokai Co., Ltd.

Latent heat recovery type non-pressure water heater TSiFTα BHC-800 series
Tomoe Shokai Co., Ltd.


About This Product

Amazing energy savings. Efficiency 105% (13A). The latent heat recovery type is environmentally friendly and economical eco-style.

■“Space saving” All devices integrated

A series of equipment such as the can body, latent heat recovery device, burner, and controller are compactly integrated. Transport and installation work is also easy. There is plenty of space for installation and sufficient space for maintenance, allowing for careful maintenance.

■“Safe structure” No qualifications or licenses required

You can use our products with peace of mind as we use our own unique system that covers everything from development and design to manufacturing and maintenance. Additionally, since the "Boiler and Pressure Vessel Safety Regulations" do not apply, no notification or qualification license is required.

■Advantages of latent heat recovery

With conventional water heaters, the heat energy remaining in the exhaust gas is released into the atmosphere without being used. Latent heat recovery type water heaters can operate efficiently by utilizing the latent heat in the exhaust gas, and by absorbing the latent heat, the exhaust gas temperature is lowered. The benefits of this system are not only reduced energy consumption, but also greenhouse gas and NOx emissions.

■No need to raise exhaust chimney

BHC-800series is a water heater that can effectively utilize the heat in exhaust gas, so the exhaust gas temperature never exceeds 100℃. Therefore, regarding the construction conditions (starting) of chimneys stipulated by the Building Standards Act Construction Ordinance and Fire Prevention Ordinance, the chimney construction conditions (starting up) stipulated by the Construction Ordinance and Fire Prevention Ordinance are such that there is no problem with fire prevention (waste gas temperature 100℃ or less). No construction (startup) is required. *If there are any special instructions from local government ordinances or the local fire department, please comply with them. It is also necessary to vent exhaust gas outdoors. Please carefully consider the surrounding conditions (buildings, windows, people, etc.) before proceeding with construction. Please be sure to check the construction manual during construction.

  • Product

    Latent heat recovery type non-pressure water heater TSiFTα BHC-800 series

Share this product


130+ people viewing


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

1 Models of Latent heat recovery type non-pressure water heater TSiFTα BHC-800 series

Image Part Number Price (excluding tax) Power capacity 2 circuits kW Power capacity 1 circuit kW Fuel consumption Water supply temperature 5℃ LPG ㎥N/h Fuel consumption Water supply temperature 5℃ 13A ㎥N/h Fuel consumption Water supply temperature 10℃ LPG ㎥N/h Fuel consumption Water supply temperature 10℃ 13A ㎥N/h Pressureless can water volume lit Rated equipment efficiency Feed water temperature 5℃ LPG % Rated equipment efficiency Water supply temperature 5℃ 13A % Rated equipment efficiency Feed water temperature 10℃ LPG % Rated equipment efficiency Water supply temperature 10℃ 13A % Rated output kW (kcal/h) Rated input Water supply temperature 5℃ LPG kW Rated input water supply temperature 5℃ 13A kW Rated input Water supply temperature 10℃ LPG kW Rated input water supply temperature 10℃ 13A kW Heat transfer area m2 2-circuit type hot water supply circuit Hot water supply amount lit/h 2-circuit type hot water circuit Maximum output kW 2-circuit hot water supply circuit Pressure loss kPa (mH2O) 2-circuit type circulation circuit Hot water circulation amount lit/min 2 circuit type circulating circuit maximum output kW 2-circuit type circulation circuit Pressure loss kPa (mH2O) 1-circuit hot water supply circuit Hot water supply amount lit/h Single-circuit hot water supply circuit Maximum output kW Single-circuit hot water supply circuit Pressure loss kPa (mH2O) 1-circuit type circulation circuit Hot water circulation amount lit/min Single circuit type circulation circuit Pressure loss kPa (mH2O) 1 circuit circulation circuit maximum output kW
Latent heat recovery type non-pressure water heater TSiFTα BHC-800 series-Part Number-BHC-825

BHC-825

Available upon quote

2.1

1.4

11.2

24.5

11.5

25.2

315

102

105

100

102

291
(250,000)

285

277

291

285

4.5

5,000

291

19.3 (2.0)

208

291

71.5 (7.3)

5,000

291

19.3 (2.0)

208

71.5 (7.3)

291

Other products of Tomoe Shokai Co., Ltd.