Ultra-low power consumption high precision data logger HKS-9700-HKS-9700
Ultra-low power consumption high precision data logger HKS-9700-NF Measurement Giken Co., Ltd.

Ultra-low power consumption high precision data logger HKS-9700
NF Measurement Giken Co., Ltd.


About This Product

The HKS-9700 series is a new generation data logger that operates with "ultimately low power consumption" and can perform earthquake measurements with higher accuracy than conventional products.

■Ultra low power consumption

Low power consumption of 0.15W (24 hour average, 3 channels/±5V input type)

■AD function

27bit 132db 4 channels simultaneous sampling

■GPS time correction

・By fixing the position, time correction is possible from one satellite capture state. ・Acquired almanac information and ephemeris information can be retained even when the main unit is powered off.

■Data recording function

・Sampled data can be continuously recorded on CF card in WIN/WIN32 format. ・Supports large capacity CF cards (operation confirmed up to 32GB)

■Network function

・By incorporating an optional telemeter board, it is possible to construct an online observation point compactly.

■“Ultimate low power consumption” of less than 0.15W (24-hour average at 100Hz)

With a more thorough power saving function than ever before, it achieves low power consumption of less than 0.15W (24-hour average, 3 channels/±5V input type).

■27bit 132dB 3 or 4 channels simultaneous sampling

It has the ability to simultaneously sample 3 or 4 channels of analog input at 100Hz/200Hz 27bit. Sampling is synchronized with accurate time information obtained from GPS satellites, and is recorded on the CF card along with the time information. The dynamic range is over 132dB at 100Hz/27bit.

■Time can be corrected even from 1 satellite capture state

The sampling data is synchronized with accurate time information obtained from GPS satellites, and is recorded on the CF card along with the time information. Normally, it is necessary to capture three or more satellites to obtain accurate time, but by using fixed position mode, time calibration can be performed from one satellite captured. The acquired almanac information and ephemeris information are retained even when the main unit is powered off.

■Enlarge the waveform display on a large screen

An organic EL display is used as the display device. The large display screen makes waveform display much easier to see. In addition, you can select the display channel and change the display scale, so you can check the waveform in detail only on the main unit.

  • Product

    Ultra-low power consumption high precision data logger HKS-9700

Share this product


50+ people viewing

Last viewed: 7 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

1 Models of Ultra-low power consumption high precision data logger HKS-9700

Image Part Number Price (excluding tax) Power supply voltage Power input Weight Corrosive gas Dust Power consumption Formal resolution External dimensions Operating humidity Operating temperature Input range Input channel Input impedance Storage humidity Storage temperature Digital filter Dynamic range Sampling frequency RS-232C Gps antenna connector EXT.Port Compact Flash Type 1
Ultra-low power consumption high precision data logger HKS-9700-Part Number-HKS-9700

HKS-9700

Available upon quote

DC9V - DC16V

3 systems (constant voltage power input x 2, battery input x 1)

Within 1.1kg

There is nothing

It's not particularly bad

0.15W or less (24 hour average, 3 channels ±5V input type)
(Input range ±5V, sampling 100sps, GPS reception interval 1 hour)

27bit / 24bit selectable (ΔΣ method)

W220×D160×H75mm (excluding protrusions)

20~90% (no condensation)

-20~50℃

±5V/±2.5V/±0.5V (±5V input type)
±15V/±5V/±0.5V (±15V input type)

Differential 3 channel type and 4 channel type

1MΩ (common mode) /2MΩ (differential)

20~90% (no condensation)

-20~65℃

Minimum phase/linear phase

132dB or more (at input range ±5V (±5V input type) or ±15V (±15V input type), minimum phase, sampling 100sps)

20sps/100sps/200sps/1,000sps

1

BNC × 1 (5V/3.3V compatible)

1

Number of slots: 1 Capacity: up to 32GB Format: FAT32

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Data Loggers Products

Other products of NF Measurement Giken Co., Ltd.

Reviews shown here are reviews of companies.


View more products of NF Measurement Giken Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree