All Categories

History

General power outage generator (automatic operation type) LEG series-LEG-9.9USXT
General power outage generator (automatic operation type) LEG series-Ikeda Shokai Co., Ltd.

General power outage generator (automatic operation type) LEG series
Ikeda Shokai Co., Ltd.


About This Product

■LP gas is a disaster-resistant energy source.

LP gas is stored energy on-site and can be used immediately even in the event of a disaster. Even when lifelines such as electricity and city gas are cut off during a disaster and it takes time to restore them, LP gas is quickly restored and is used in temporary housing and evacuation centers as a fuel for cooking, hot water, space heating, etc. For this reason, LP gas is attracting attention as a ``disaster-resistant energy source.''

■LP gas is an energy source with little fuel deterioration.

LP gas is an energy that can be stored for long periods of time, with less deterioration compared to fuels like gasoline and diesel oil.

■LP gas is easy and reliable to procure.

LP gas is delivered and supplied by the contracted gas company, so there is no need for customers to procure it themselves. In addition, filling stations are being set up across the country that allow remote gas level monitoring and delivery even during power outages.

■Low noise design that does not cause stress to surrounding areas.

Denyo's unique thorough soundproofing design has achieved exceptionally low noise. The noise level is comparable to that of an outdoor air conditioner unit, so driving in residential areas or at night will not cause stress to those around you.

■Provides stable power comparable to commercial power sources

Due to the reinforced damper winding, this generator has low waveform distortion even under rectifier loads and has high negative phase tolerance. In addition, the voltage fluctuation rate is extremely low, making it suitable for precision equipment such as inverter loads, thyristor loads, and computer-controlled loads.

■40 seconds until power is transmitted. Power is transmitted fully automatically.

Automatically starts in the event of a commercial power outage and transmits power from the generator. When commercial power is restored, the power will be automatically turned off and the system will automatically stop after standby operation. Manual operation is also possible.

■Automatic maintenance operation

By setting a timer once a week, the engine will automatically start according to the customer's wishes, and after a certain period of no-load operation, it will automatically stop. The operation day can be set to any day of the week and time.

■Equipped with various protection devices

Equipped with a circuit breaker that protects the generator from short circuits and overloads in the load circuit, and an emergency stop device and warning light that detects engine abnormalities and automatically stops the generator. has been.

■Clean exhaust gas

LP gas is a clean exhaust gas that does not contain particulate matter (PM) or black smoke.

■Cubicle structure

Surrounding distance can be minimized.

  • Product

    General power outage generator (automatic operation type) LEG series

Share this product


40+ people viewing

Last viewed: 22 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

1 Models of General power outage generator (automatic operation type) LEG series

Image Part Number Price (excluding tax) Power switch Voltage 60Hz Voltage 50Hz Storage battery capacity V-Ah Storage battery model Insulation type Number of phases/power factor Fuel type Fuel consumption (at 100% load) 60Hz kg/h Fuel consumption (at 100% load) 60Hz Fuel consumption (at 100% load) 50Hz kg/h Fuel consumption (at 100% load) 50Hz Institution name Number of poles/rotation speed 60Hz min-1 Number of poles/rotation speed 50Hz min-1 Rated output 60Hz kVA Rated output 50Hz kVA Starting method Rotation speed 60Hz min-1 Rotation speed 50Hz min-1 Excitation method Output 60Hz kW Output 50Hz kW Cooling method Charger Manufacturer Gas engine type Format
General power outage generator (automatic operation type) LEG series-Part Number-LEG-9.9USXT

LEG-9.9USXT

Available upon quote

Equipped with 50A (option not included)

110/220V

100/200V

12-40

REH type control valve type lead

Heat resistance class F

Single phase 3 wire 1.0

LP gas JIS Class 1 No. 1 (separate cylinder) Supply pressure 2.8kPa

3.1

1.6Nm3/h

2.5

1.3Nm3/h

1KS

4P 1,800

4P 1,500

9.9

8

Electric starting method

1,800

1,500

Brushless excitation

13.5

11

Radiator

Fully automatic transistor method

Toyota Industries

Water-cooled 4-cycle, vertical, series, Heron type

Rotating field type synchronous generator/open protection type

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Emergency Power Generators Products

Other products of Ikeda Shokai Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Ikeda Shokai Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree