Product
Ultrasonic flowmeter for pure water and chemical liquids Ultrasonic Karman vortex flowmeter USL-20LHandling Company
Regal Joint Co., Ltd.Categories
Image | Part Number | Price (excluding tax) | Power supply | Piping connection | Mass | Display method | Accuracy | Current consumption | Flow rate | Fluid temperature | Flow direction | Maximum working pressure | Wetted parts material | Ambient temperature | Installation direction | Fluid used | Pulse output | Cable | Analog output |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
USL-20L |
Available upon quote |
DC 12V ~ DC 24V |
Φ1 / 2" (φ12.7 × 9.53) |
Approximately 72g |
Flow display: green LED |
F.S.±2.0% |
MAX 40mA (MAX 60mA when DC 1 ~ 5V, 4 ~ 20mA output) |
2.0~20L/min |
0 ~ 100℃ (Cannot freeze or boil) |
Specified direction |
1MPa (less than 10kgf / square centimeter) |
PFA |
0~60℃ |
Freedom |
Pure water, chemical solution, industrial water, water (no bubbles) |
Open collector (MAX DC 40V・100mA) |
AWM20276 4-core |
DC 0 ~ 10V or 1 ~ 5V or 4 ~ 20mA |