This product is registered by Daikin Lubricating Equipment Co., Ltd..
About This Product
■Summary
This electric control panel is used for UE and U type electric grease pumps. The centralized lubrication system can be used with confidence, and because it operates automatically, it is part of the labor-saving efforts of the factory.
■Characteristics of electrical control panel
This control panel has two functions: operation and alarm.
■Driving
The pump starts automatically by a timer and stops automatically when refueling is completed. In addition, manual intervention is possible at any time during automatic operation.
■Alarm
In the following cases, an alarm will occur and the failure indicator light will come on and the pump will stop.
・Extension of refueling time
・Tank empty
・Overload operation
・High pressure abnormality