Liquid cooling device LCP inline DX, LCP inline DX/FC-SK 3313.390
Liquid cooling device LCP inline DX, LCP inline DX/FC-SK 3313.430
Liquid cooling device LCP inline DX, LCP inline DX/FC-Rittal GmbH & Co. KG

Liquid cooling device LCP inline DX, LCP inline DX/FC
Rittal GmbH & Co. KG

Rittal GmbH & Co. KG's Response Status

Response Rate

100.0%

Response Time

32.5hours

Relatively Fast Response


About This Product

■Summary

Ideal for cooling small to medium sized IT applications.

■Advantages

・Maximum energy efficiency thanks to EC fan technology and IT-oriented control technology - Low pressure loss on the air side, which minimizes fan energy consumption ・Temperature monitoring and temperature control ・Equipped with a redundant temperature sensor on the air side as standard - Inverter-controlled compressors match cooling capacity to demand. - When performing LCP DX-specific maintenance, separate the server enclosure and cooling device.

■Function method

- LCP for installation in connected enclosures. Warm air is drawn through the air passages at the back of the equipment, cooled through high-performance heat exchanger registers, and then blown back into the room or cold aisle. -The absorbed thermal energy is released around the condenser outside, so there is no temperature rise in the installation room.

■Options

・Humidification device ・Dehumidification and additional heating equipment ・Condensed water pump ・Low temperature condenser / high temperature condenser (-40 ℃ / +53 ℃)

  • Product

    Liquid cooling device LCP inline DX, LCP inline DX/FC

Share this product


270+ people viewing

Last viewed: 5 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

7 Models of Liquid cooling device LCP inline DX, LCP inline DX/FC

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Height (mm) Noise level Air volume (unobstructed flow) Power connection Applicable fuse Applicable enclosure type Installed in applicable enclosure Adjustment range (kW) Total cooling capacity / number of fan modules Fans can be replaced even during operation Purpose Temperature control Material Maximum cooling capacity Width (mm) Rated current maximum Rated voltage Depth (mm) Paint color Operating temperature range Coolant Protection class according to EN 60 529 Specification Monitoring Duty cycle (%) SNMP card EC fan 1 pack (pieces) Total cooling capacity according to DIN EN 14511 Storage temperature range
Liquid cooling device LCP inline DX, LCP inline DX/FC-Part Number-SK 3313.390

SK 3313.390

Available upon quote

2,000

At 50 Hz: 68 dB (A)

For 50 Hz: 4,800 m^3/h

Terminal block wiring method

Circuit breaker/blow type fuse: 32 A

VX IT

One side

5-20

20kW/4

Yes

Ideal for cooling small and medium-sized server rooms. One or two racks can be cooled separately.

Stepless fan control, inverter controlled compressor

Steel plate, painted

20kW

300

At 50 Hz: 12.4 A

380 V~480 V, three phase, 50 Hz/60 Hz

1,200

RAL 7035

-

Refrigerant

IP20

DX

Direct connection of SNMP equipment via Ethernet. Integration into RiZone

100

Yes

Yes

1

Effective cooling capacity L22 L35: 20 kW

-20℃...50℃

Liquid cooling device LCP inline DX, LCP inline DX/FC-Part Number-SK 3313.430

SK 3313.430

Available upon quote

2,000

At 50 Hz: 68 dB (A)

For 50 Hz: 4,800 m^3/h

Terminal block wiring method

Circuit breaker/blow type fuse: 20 A

VX IT

One side

3-12

12kW/4

Yes

Ideal for cooling small and medium-sized server rooms. One or two racks can be cooled separately.

Stepless fan control, inverter controlled compressor

Steel plate, painted

12kW

300

At 50Hz: 7.5A

380 V~480 V, three phase, 50 Hz/60 Hz

1,000

RAL 7035

5℃...35℃

Refrigerant

IP20

DX

Direct connection of SNMP equipment via Ethernet. Integration into RiZone

100

Yes

Yes

1

Useful cooling output L22 L35: 12 kW, Useful cooling output L22 L45: 10 kW

-20℃...50℃

Liquid cooling device LCP inline DX, LCP inline DX/FC-Part Number-SK 3313.440

SK 3313.440

Available upon quote

2,000

At 50 Hz: 69 dB (A)

For 50 Hz: 4,800 m^3/h

Terminal block wiring method

Circuit breaker/blow type fuse: 20 A

VX IT

One side

3-12

12kW/4

Yes

Ideal for cooling small and medium-sized server rooms. One or two racks can be cooled separately.

Stepless fan control, inverter controlled compressor

Steel plate, painted

12kW

300

At 50Hz: 7.5A

380 V~480 V, three phase, 50 Hz/60 Hz

1,200

RAL 7035

5℃...35℃

Refrigerant

IP20

DX

Direct connection of SNMP equipment via Ethernet. Integration into RiZone

100

Yes

Yes

1

Useful cooling output L22 L35: 12 kW, Useful cooling output L22 L45: 10 kW

-20℃...50℃

Liquid cooling device LCP inline DX, LCP inline DX/FC-Part Number-SK 3313.450

SK 3313.450

Available upon quote

2,000

At 50 Hz: 68 dB (A)

At 50 Hz: 9,900 m^3/h

Terminal block wiring method

Circuit breaker/blow type fuse: 40 A

VX IT

One side

8-35

35kW/3

Yes

Ideal for cooling small and medium-sized server rooms. One or two racks can be cooled separately.

Stepless fan control, inverter controlled compressor

Steel plate, painted

35kW

600

At 50 Hz: 22.4 A

380 V~480 V, three phase, 50 Hz/60 Hz

1,000

RAL 7035

5℃...35℃

Refrigerant

IP20

DX

Direct connection of SNMP equipment via Ethernet. Integration into RiZone

100

Yes

Yes

1

- -
Liquid cooling device LCP inline DX, LCP inline DX/FC-Part Number-SK 3313.460

SK 3313.460

Available upon quote

2,000

At 50 Hz: 68 dB (A)

At 50 Hz: 9,900 m^3/h

Terminal block wiring method

Circuit breaker/blow type fuse: 50 A

VX IT

One side

8-35

35kW/3

Yes

Ideal for cooling small and medium-sized server rooms. One or two racks can be cooled separately.

Stepless fan control, inverter controlled compressor

Steel plate, painted

35kW

600

At 50 Hz: 31.6 A

380 V~480 V, three phase, 50 Hz/60 Hz

1,000

RAL 7035

5℃...35℃

Refrigerant

IP20

DX/FC

Direct connection of SNMP equipment via Ethernet. Integration into RiZone

100

Yes

Yes

1

- -
Liquid cooling device LCP inline DX, LCP inline DX/FC-Part Number-SK 3313.470

SK 3313.470

Available upon quote

2,000

At 50 Hz: 68 dB (A)

At 50 Hz: 9,900 m^3/h

Terminal block wiring method

Circuit breaker/blow type fuse: 40 A

VX IT

One side

8-35

35kW/3

Yes

Ideal for cooling small and medium-sized server rooms. One or two racks can be cooled separately.

Stepless fan control, inverter controlled compressor

Steel plate, painted

35kW

600

At 50 Hz: 22.4 A

380 V~480 V, three phase, 50 Hz/60 Hz

1,200

RAL 7035

5℃...35℃

Refrigerant

IP20

DX

Direct connection of SNMP equipment via Ethernet. Integration into RiZone

100

Yes

Yes

1

- -
Liquid cooling device LCP inline DX, LCP inline DX/FC-Part Number-SK 3313.480

SK 3313.480

Available upon quote

2,000

At 50 Hz: 69 dB (A)

At 50 Hz: 9,900 m^3/h

Terminal block wiring method

Circuit breaker/blow type fuse: 50 A

VX IT

One side

8-35

35kW/3

Yes

Ideal for cooling small and medium-sized server rooms. One or two racks can be cooled separately.

Stepless fan control, inverter controlled compressor

Steel plate, painted

35kW

600

At 50 Hz: 31.6 A

380 V~480 V, three phase, 50 Hz/60 Hz

1,000

RAL 7035

5℃...35℃

Refrigerant

IP20

DX/FC

Direct connection of SNMP equipment via Ethernet. Integration into RiZone

100

Yes

Yes

1

- -

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Server Racks Products

Other products of Rittal GmbH & Co. KG

Reviews shown here are reviews of companies.


View more products of Rittal GmbH & Co. KG

About Company Handling This Product

Response Rate

100.0%


Response Time

32.5hrs

Company Overview

Rittal is a German manufacturer of electrical enclosures and related products that was established in Herborn,...

See More

  • Germany