Sanitary environment design wall type HD water-cooled heat exchangerHandling Company
Rittal GmbH & Co. KGCategories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Height (mm) | Applicable fuse | Water temperature | Mass/pack (kg) | Maximum permissible pressure (p max) | Setting range | Surface | Temperature monitoring | Temperature control | Note | Water pipe connection | Material | Width (mm) | Rated current maximum | Rated voltage | Rated output Pel | Depth (mm) | Operating temperature range | Cooling capacity | Coolant | Protection class according to EN 60 529 | Specification | Duty cycle | Protection category NEMA | 1 pack (pieces) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SK 3214.700 |
Available upon quote |
526 |
Circuit breaker/blow type fuse: 2 A |
1℃...30℃ |
6 |
1 - 10 bar |
20℃...60℃ |
Housing: hairline finish, grain size #400, surface roughness < 0.8 µm |
Built-in thermostat with switching contact (C contact), contact capacity 16 A, setting range +20 °C to +60 °C (factory setting +35 °C) |
Thermostatically controlled solenoid valve |
To achieve protection class IP 66 / 69 according to IEC 60 529, air ingress through the condensate drain must be completely blocked. |
G ⅜ inch male thread |
Enclosure: Stainless steel, 1.4301 (AISI 304) |
220 |
For 50 Hz: 0.16 A, for 60 Hz: 0.14 A |
230 V, single phase, 50 Hz/60 Hz |
For 50 Hz: 33 W, for 60 Hz: 34 W |
100 |
1℃...70℃ |
L 35 W 10 (at 200 l/h): 0.6 kW, L 35 W 10 (at 400 l/h): 0.65 kW |
Water |
IP56/59 |
Wall type |
100% |
NEMA 4X |
1 |
|
SK 3215.700 |
Available upon quote |
982 |
Circuit breaker/blow type fuse: 4 A |
1℃...30℃ |
14 |
1 - 10 bar |
20℃...60℃ |
Housing: hairline finish, grain size #400, surface roughness < 0.8 µm |
Built-in thermostat with switching contact (C contact), contact capacity 16 A, setting range +20 °C to +60 °C (factory setting +35 °C) |
Thermostatically controlled solenoid valve |
To achieve protection class IP 66 / 69 according to IEC 60 529, air ingress through the condensate drain must be completely blocked. |
G ⅜ inch male thread |
Enclosure: Stainless steel, 1.4301 (AISI 304) |
215 |
For 50 Hz: 0.38 A, for 60 Hz: 0.47 A |
230 V, single phase, 50 Hz/60 Hz |
At 50 Hz: 77 W, at 60 Hz: 104 W |
100 |
1℃...70℃ |
L 35 W 10 (at 200 l/h): 1 kW, L 35 W 10 (at 400 l/h): 1.2 kW |
Water |
IP56/59 |
Wall type |
100% |
NEMA 4X |
1 |
Click on the part number for more information about each product