All Categories
History
Response Rate
100.0%
Response Time
17.6hours
Relatively Fast Response
Product
Perform all necessary measurements with one unit Multifunctional mass flowmeter for gases MASS FLOW MULTI-METER Model5303 (high flow model)Handling Company
TranstecCategories
Image | Part Number | Price (excluding tax) | Power supply | Absolute pressure measurement accuracy | Absolute pressure measurement range | Absolute pressure measurement response time | Absolute pressure measurement unit | Accuracy | Integral measurement accuracy | Integral measurement range | Integral measurement unit | Relative humidity measurement accuracy | Relative humidity measurement range | Relative humidity measurement response time | Relative humidity measurement unit | Temperature measurement accuracy | Temperature measurement range | Temperature measurement response time | Temperature measurement unit | Flow measurement range | Flow measurement calibration gas | Equipment temperature range | Response time unit | Response time | Pressure range Operating range | Volume measurement accuracy | Volume measurement range | Volume measurement unit | Low differential pressure/breathing circuit measurement accuracy | Low differential pressure/breathing circuit measurement range | Low differential pressure/breathing circuit measurement response time | Low differential pressure/breathing circuit measurement unit |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Model5303 |
Available upon quote |
Powered by USB-C port |
±1kPa |
50~200kPa |
4ms or less (when reaching 63% of final value) |
Pa,hPa,kPa,mbar,PSI,mmHG,cmH2O,inH2O |
0.1L/min (whichever is larger) |
±4% of reading |
0.05~400,000L |
L,mL,ft3 |
±3% of RH |
10~90%RH |
3 seconds or less (when reaching 63% of final value) |
%RH, dew point (℃,℉) |
±1℃ when flow rate is greater than 1StdL/min (forward direction only) |
-10~50℃ |
75ms or less (when reaching 63% of final value) |
℃、℉ |
0~±300StdL/min/0~100StdL/min (CO2) |
Air, O2, CO2, N2 (user selectable) |
Operation: -10~50℃ (ambient temperature) |
L/min or ft3/min (standard, volumetric, actual flow, or remote) |
4ms: 63% of full scale |
50~200kpa |
2% of reading or 1ml, whichever is greater (when peak flow is greater than 2.5StdL/min) |
0.004~99L |
L,mL,ft3 |
±0.5% of reading or 0.15cmH2O, whichever is greater |
±150cmH2O |
4ms or less (when reaching 63% of final value) |
Pa,hPa,kPa,mbar,PSI,mmHG,cmH2O,inH2O |
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.
Response Rate
100.0%
Response Time
17.6hrs