Standard AC/DC Resistor 5430-5430-1
Standard AC/DC Resistor 5430-Fluke Calibration

Standard AC/DC Resistor 5430
Fluke Calibration


About This Product

■Best performance as an AC/DC resistor

・Long-term stability of 2 ppm or less per year (standard value 1 ppm) ・Traceable AC/DC calibration available ・National laboratory design with over 25 years of experience Tinsley standard AC/DC resistors have long been trusted by national laboratories around the world. Whether for temperature measurement or electrical applications, whether with an AC or DC bridge, these resistors outperform other AC/DC resistors. Fluke Calibration's Model 5430 series of six resistors range in resistance from 1 Ω to 10,000 Ω. The actual resistance of each resistor is within 10 ppm of its nominal value, keeping its resistance to within 2 ppm over a one-year period. All resistors come with Tinsley's certificate of AC performance and have a calibration uncertainty of 3 ppm with NPL traceability. Fluke Calibration can also optionally offer DC certification, NIST and NVLAP certification, and sub-1 ppm uncertainty resistors. Originally designed by National Labs, Tinsley resistors are double-wound to minimize induced resistance and oil-filled to minimize instability with both time and temperature. The AC/DC conversion error at 90 Hz is only 0.1 ppm. With oil resistor maintenance in mind, Fluke Calibration offers baths in capacities from 25 liters to 155 liters with enough internal shelf space to service all standard resistors. These baths will hold the resistor within 1 mK for short periods of time (30 to 60 minutes) and within 5 mK for several months.

  • Product

    Standard AC/DC Resistor 5430

Share this product


60+ people viewing

Last viewed: 18 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

1 Models of Standard AC/DC Resistor 5430

Image Part Number Price (excluding tax) Long term stability Tolerance Temperature coefficient Calibration uncertainty Maximum current Recommended current AC/DC conversion error (at 90 Hz)
Standard AC/DC Resistor 5430-Part Number-5430-1

5430-1

Available upon quote

2 ppm in 1 year

10ppm

2 ppm per ℃

AC: 3 ppm (10 kΩ: 4 ppm) DC: 1 ppm (optional)

1Ω: 1A
10Ω: 320mA
25Ω: 200mA
100Ω: 100mA
1 kΩ: 32 mA
10 kΩ: 10 ma

1Ω: 100mA
10Ω: 32mA
25Ω: 20mA
100Ω: 10mA
1 kΩ: 3 mA
10 kΩ: 1 mA

0.1 ppm, typical value

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Fixed Resistors Products

Other products of Fluke Calibration

Reviews shown here are reviews of companies.


View more products of Fluke Calibration

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree