Electrical safety tester calibrator 5322AHandling Company
Fluke CalibrationCategories
Image | Part Number | Price (excluding tax) | Altitude | Power supply | Weight | Test voltage measurement range | Correction COMP mode (active loop correction) | Relative humidity (storage) | Relative humidity (operating) | Leakage current output Test voltage Passive mode | Leakage current output range | Compliant standards Safety standards | Temperature performance Calibration temperature (tcal) | Temperature performance Storage temperature | Temperature performance Storage recovery time | Temperature performance Operating temperature | Power consumption | Manual/scan mode correction | External dimensions | Low resistance output range | Specification interval | Specification confidence level | Line/loop impedance output range | Fuse protection Leakage current input | Fuse protection loop/line impedance input | Fuse protection meter current (A) input | Fuse protection RCD input | Fuse protection AC mains input | Warm up time | Earth continuity resistance output Resistance mode Range | 5.5 kV high resistance output (DC only) range | 1.5 kV high resistance output (DC only) range |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
5322A |
Available upon quote |
Operating: 3,050 m |
115/230Vac (50/60Hz) +10% / -14% |
20 kg |
0V DC ~ 5,500V DC |
Maximum compensation impedance: 0 Ω ~ 2 Ω |
90% from 0°C to 50°C (non-condensing) |
80% up to 28°C (70% up to 28°C with resistance output 10 GΩ or more) |
± (0.3% of setting + 2 μA) |
0.1~30mA |
Mains power supply: IEC 61010-1: Overvoltage category II, pollution degree 2 |
23℃ |
-10℃~50℃ |
Typical within 24 hours at operating temperature |
18℃~28℃ |
Up to 1250VA |
Residual impedance range: 0 Ω to 10 Ω |
430mm x 555mm x 170mm |
100 mΩ ~ 10 kΩ + 10 mΩ single value selection, DC and mains frequency (50/60 Hz) |
1 year |
99% |
25 mΩ ~ 1,700 Ω |
100 mA / 250 V, fast acting (F100 mL250 V – 5 mm x 20 mm) |
4 A / 500 V, delay (T4H500 V – 6.3 mm x 32 mm) |
20 A / 500 V, delay (F20H500 V – 6.3 mm x 32 mm) |
3.15 A / 250 V, fast acting (F3.15H250 V – 5 mm x 20 mm) |
2A / 250V (for 230V), delay (T2L250V – 5 mm x 20 mm); 4A / 250V (for 115V), delay (T4L250V–5mm x 20mm) |
15 minutes |
1 mΩ ~ 1,700 Ω, DC and line frequency (50/60 Hz) |
10 kΩ ~ 100 GΩ |
10 kΩ ~ 10 GΩ + 100 GΩ single value selection |