All Categories

History

Air hand (mechanical parallel type) HFP series-HFP10
Air hand (mechanical parallel type) HFP series-Nakajima Koki Co., Ltd.

Air hand (mechanical parallel type) HFP series
Nakajima Koki Co., Ltd.

Nakajima Koki Co., Ltd.'s Response Status

Response Rate

100.0%

Response Time

46.8hours


About This Product

■Installation and use

・Install a fall prevention device. ・Do not use pneumatic fingers when external force or impact force is large. - When installing or fixing the pneumatic finger, be careful not to drop, impact, or damage it. - Do not twist the club when hardening the club parts. ・There are several ways to attach the fingers, and please tighten them within the maximum tightening torque range. If it is too large, it may cause malfunction, and if the tightening torque is insufficient, it may cause it to shift in position or fall.

■Features

・Since it has a leverage grab structure and opens and closes in parallel, it is possible to reduce costs and improve cost effectiveness if accuracy is met. -There is a metal sheet between the club and the main body, which reduces wear and extends the service life. - By increasing the contact area within the main body of the grab, shaking is reduced and grip precision is improved. -The operating method is to pinch the piston rod when it is pushed out, and open it when it returns. The force when pinching is 20% to 30% greater than the force when returning. - Can be installed from three sides, so it can be used in a variety of locations. - All come with magnets as standard, so they can be easily controlled.

  • Product

    Air hand (mechanical parallel type) HFP series

Share this product


350+ people viewing


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

10 Models of Air hand (mechanical parallel type) HFP series

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Piping connection size Refueling Maximum crawl mm Ambient and working fluid temperature Operation method Inner diameter (mm) Remarks Guaranteed pressure resistance Fluid used Maximum frequency used Working pressure range Attached sensor switch ①
Air hand (mechanical parallel type) HFP series-Part Number-HFP10

HFP10

Available upon quote

M3 × 0.5

Cylinder part: Not required, Glove movable part: Required (apply grease to parts that move relative to each other)

30

-10~70℃

Double acting

10

①Sensor switch must be ordered separately.

1.05Mpa (150psi) (10.5bar)

Air (Please use air filtered with a filter of 40μm or more)

180 (c.p.m.)

0.2~0.6Mpa (28~100psi) (2.0~7.0bar)

-
Air hand (mechanical parallel type) HFP series-Part Number-HFP16

HFP16

Available upon quote

M5×0.8

Cylinder part: Not required, Glove movable part: Required (apply grease to parts that move relative to each other)

40

-10~70℃

Double acting

16

①Sensor switch must be ordered separately.

1.05Mpa (150psi) (10.5bar)

Air (Please use air filtered with a filter of 40μm or more)

180 (c.p.m.)

0.1~0.7Mpa (15~100psi) (1.0~7.0bar)

CS1-G/DS1-G

Air hand (mechanical parallel type) HFP series-Part Number-HFP20

HFP20

Available upon quote

M5×0.8

Cylinder part: Not required, Glove movable part: Required (apply grease to parts that move relative to each other)

60

-10~70℃

Double acting

20

①Sensor switch must be ordered separately.

1.05Mpa (150psi) (10.5bar)

Air (Please use air filtered with a filter of 40μm or more)

180 (c.p.m.)

0.1~0.7Mpa (15~100psi) (1.0~7.0bar)

CS1-G/DS1-G

Air hand (mechanical parallel type) HFP series-Part Number-HFP25

HFP25

Available upon quote

M5×0.8

Cylinder part: Not required, Glove movable part: Required (apply grease to parts that move relative to each other)

70

-10~70℃

Double acting

Twenty five

①Sensor switch must be ordered separately.

1.05Mpa (150psi) (10.5bar)

Air (Please use air filtered with a filter of 40μm or more)

180 (c.p.m.)

0.1~0.7Mpa (15~100psi) (1.0~7.0bar)

CS1-G/DS1-G

Air hand (mechanical parallel type) HFP series-Part Number-HFP32

HFP32

Available upon quote

M5×0.8

Cylinder part: Not required, Glove movable part: Required (apply grease to parts that move relative to each other)

90

-10~70℃

Double acting

32

①Sensor switch must be ordered separately.

1.05Mpa (150psi) (10.5bar)

Air (Please use air filtered with a filter of 40μm or more)

60 (c.p.m.)

0.1~0.7Mpa (15~100psi) (1.0~7.0bar)

CS1-G/DS1-G, DS1-H

Air hand (mechanical parallel type) HFP series-Part Number-HFTP10

HFTP10

Available upon quote

M3 × 0.5

Cylinder part: Not required, Glove movable part: Required (apply grease to parts that move relative to each other)

30

-10~70℃

Single acting type

10

①Sensor switch must be ordered separately.

1.05Mpa (150psi) (10.5bar)

Air (Please use air filtered with a filter of 40μm or more)

180 (c.p.m.)

0.35~0.7Mpa (50~100psi) (3.5~7.0bar)

-
Air hand (mechanical parallel type) HFP series-Part Number-HFTP16

HFTP16

Available upon quote

M5×0.8

Cylinder part: Not required, Glove movable part: Required (apply grease to parts that move relative to each other)

40

-10~70℃

Single acting type

16

①Sensor switch must be ordered separately.

1.05Mpa (150psi) (10.5bar)

Air (Please use air filtered with a filter of 40μm or more)

180 (c.p.m.)

0.25~0.7Mpa (36~100psi) (2.5~7.0bar)

CS1-G/DS1-G

Air hand (mechanical parallel type) HFP series-Part Number-HFTP20

HFTP20

Available upon quote

M5×0.8

Cylinder part: Not required, Glove movable part: Required (apply grease to parts that move relative to each other)

60

-10~70℃

Single acting type

20

①Sensor switch must be ordered separately.

1.05Mpa (150psi) (10.5bar)

Air (Please use air filtered with a filter of 40μm or more)

180 (c.p.m.)

0.25~0.7Mpa (36~100psi) (2.5~7.0bar)

CS1-G/DS1-G

Air hand (mechanical parallel type) HFP series-Part Number-HFTP25

HFTP25

Available upon quote

M5×0.8

Cylinder part: Not required, Glove movable part: Required (apply grease to parts that move relative to each other)

70

-10~70℃

Single acting type

Twenty five

①Sensor switch must be ordered separately.

1.05Mpa (150psi) (10.5bar)

Air (Please use air filtered with a filter of 40μm or more)

180 (c.p.m.)

0.25~0.7Mpa (36~100psi) (2.5~7.0bar)

CS1-G/DS1-G

Air hand (mechanical parallel type) HFP series-Part Number-HFTP32

HFTP32

Available upon quote

M5×0.8

Cylinder part: Not required, Glove movable part: Required (apply grease to parts that move relative to each other)

90

-10~70℃

Single acting type

32

①Sensor switch must be ordered separately.

1.05Mpa (150psi) (10.5bar)

Air (Please use air filtered with a filter of 40μm or more)

60 (c.p.m.)

0.25~0.7Mpa (36~100psi) (2.5~7.0bar)

CS1-G/DS1-G, DS1-H

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Air Chucks Products

Other products of Nakajima Koki Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Nakajima Koki Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

46.8hrs

  • Japan