All Categories

History

Data logger Lineup of 2 models: high voltage/high accuracy and standard Isolated multi-channel data logger midi LOGGER GL840 series-GL840-M
Data logger Lineup of 2 models: high voltage/high accuracy and standard Isolated multi-channel data logger midi LOGGER GL840 series-Meishin Koki Co., Ltd.

Data logger Lineup of 2 models: high voltage/high accuracy and standard Isolated multi-channel data logger midi LOGGER GL840 series
Meishin Koki Co., Ltd.

Meishin Koki Co., Ltd.'s Response Status

Response Rate

100.0%

Response Time

17.9hours

Relatively Fast Response


About This Product

■Summary

Two model lineup: “Standard” and “High withstand voltage/high precision” Features

■Wide expandability with 3 types of input phones

・Input 1: Analog input port (isolated multi-function input) ・Input 2: Digital sensor connection port, GL100 sensor and terminal/adapter can be connected, expanding the range of measurements ・Input 3: Logic/pulse port, 4 channels of logic or pulse signals can be input

■Channel expansion of analog signal input port

・Can be expanded in increments of 20 channels from standard 20 channels to maximum 200 channels ・Using an extension terminal connection cable (2 types: 50cm/2m), it is possible to communicate between the main unit and terminals or between terminals.

■Supports sampling speed up to 10ms

By narrowing down the number of channels, data can be recorded at a maximum of 10ms.

■Wireless measurement with wireless LAN unit

・When the optional wireless LAN unit (B-568) is installed, wireless measurement can be performed in "master mode" or "slave mode" depending on the purpose. ・GLT400 and GL100 can be used as slave devices

■Select internal memory

Possible to flexibly respond to customer's internal regulations

■Standard memory (GL840-M / GL840-WV)

Built-in 8GB memory

■SD memory (GL840-SDM / GL840-SDWV)

Wireless LAN unit or SD card can be installed (cannot be installed at the same time)

■Can be connected to thermal printer DP-581H

・Wireless connection is possible using the optional wireless LAN unit (B-568) ・Data can be handed over on the spot, contributing to data tampering prevention

  • Product

    Data logger Lineup of 2 models: high voltage/high accuracy and standard Isolated multi-channel data logger midi LOGGER GL840 series

Share this product


120+ people viewing

Last viewed: 8 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

1 Models of Data logger Lineup of 2 models: high voltage/high accuracy and standard Isolated multi-channel data logger midi LOGGER GL840 series

Image Part Number Price (excluding tax) Mass Display screen Display characters Display Vibration resistance Power consumption External output External input External memory slot External dimensions Recording function Playback data Built-in memory Usage environment Battery pack Sampling interval Number of analog terminal units installed Analog terminal unit type PC I/F DC input AC adapter A/D converter
Data logger Lineup of 2 models: high voltage/high accuracy and standard Isolated multi-channel data logger midi LOGGER GL840 series-Part Number-GL840-M

GL840-M

Available upon quote

GL840-M: 1,010g GL840-WV: 1,035g

Waveform + digital screen, all waveform screen, digital + calculation screen, enlarged digital screen, integrated bar graph screen

Japanese, English, French, German, Chinese, Korean, Russian, Spanish

Size 7 inch TFT color LCD (WVGA: 800 x 480 dots)

Equivalent to Automotive Parts Class 1 Class A

38VA or less (using AC adapter, LCD ON, battery pack charging, AC100V)

Alarm output 4ch

1ch trigger input or 1ch external sample input,
4ch logic input or 4ch pulse input
Maximum input frequency: 50kHz
Maximum count: 50kC/sampling

SD2 slot: SDHC compatible, up to approximately 32GB memory usable (cannot be used when wireless LAN unit (B-568) is installed.)

GL840-M: 240×158×52.5mm GL840-WV: 240×158×52.5mm (high voltage terminal block included)

OFF/Ring recording/Relay recording
・Ring recording: When the number of recorded points is exceeded, data is recorded while deleting old data.
・Relay recording: Separate files into 2GB units and record continuously without missing any data.

GBD/CSV format (data recorded with GL840 only)

GL840-M/WV: Approx. 8GB (built-in fixed) GL840-SDM/SDWV: Approx. 8GB (SD memory card included, can be removed from slot)

0~45℃, 5~85%RH (0~40℃ when running on battery/15~35℃ when charging)

Up to 2 DC7.2V (2,900mAh) can be installed (battery pack option)

10ms~1h (10~50ms is voltage only, limited number of channels), external

1 unit (20ch) or expansion unit (maximum 200ch)

Standard terminal, high voltage high precision terminal, screwless terminal (optional)

Ethernet (10BASE-T/100BASE-TX), USB2.0, Wireless LAN (Option: B-568 required)

DC8.5~24V

AC100~240V/50~60Hz

⊿Σ method, 16Bit (effective resolution: ±1/40,000 of range)

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Data Loggers Products

Other products of Meishin Koki Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Meishin Koki Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

17.9hrs


Company Review

5.0
  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2025 Metoree