Data logger Lineup of 2 models: high voltage/high accuracy and standard Isolated multi-channel data logger midi LOGGER GL840 series-GL840-M
Data logger Lineup of 2 models: high voltage/high accuracy and standard Isolated multi-channel data logger midi LOGGER GL840 series-Meishin Koki Co., Ltd.

Data logger Lineup of 2 models: high voltage/high accuracy and standard Isolated multi-channel data logger midi LOGGER GL840 series
Meishin Koki Co., Ltd.


About This Product

■Summary Two model lineup: “Standard” and “High withstand voltage/high precision” Features ■Wide expandability with 3 types of input phones ・Input 1: Analog input port (isolated multi-function input) ・Input 2: Digital sensor connection port, GL100 sensor and terminal/adapter can be connected, expanding the range of measurements ・Input 3: Logic/pulse port, 4 channels of logic or pulse signals can be input ■Channel expansion of analog signal input port ・Can be expanded in increments of 20 channels from standard 20 channels to maximum 200 channels ・Using an extension terminal connection cable (2 types: 50cm/2m), it is possible to communicate between the main unit and terminals or between terminals. ■Supports sampling speed up to 10ms By narrowing down the number of channels, data can be recorded at a maximum of 10ms. ■Wireless measurement with wireless LAN unit ・When the optional wireless LAN unit (B-568) is installed, wireless measurement can be performed in "master mode" or "slave mode" depending on the purpose. ・GLT400 and GL100 can be used as slave devices ■Select internal memory Possible to flexibly respond to customer's internal regulations ■Standard memory (GL840-M / GL840-WV) Built-in 8GB memory ■SD memory (GL840-SDM / GL840-SDWV) Wireless LAN unit or SD card can be installed (cannot be installed at the same time) ■Can be connected to thermal printer DP-581H ・Wireless connection is possible using the optional wireless LAN unit (B-568) ・Data can be handed over on the spot, contributing to data tampering prevention

  • Product

    Data logger Lineup of 2 models: high voltage/high accuracy and standard Isolated multi-channel data logger midi LOGGER GL840 series

Share this product


50+ people viewing


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

1 Models of Data logger Lineup of 2 models: high voltage/high accuracy and standard Isolated multi-channel data logger midi LOGGER GL840 series

Product Image Part Number Price (excluding tax) A/D converter AC adapter Analog terminal unit type Battery pack Built-in memory DC input Display Display characters Display screen External dimensions External input External memory slot External output Mass Number of analog terminal units installed PC I/F Playback data Power consumption Recording function Sampling interval Usage environment Vibration resistance
Data logger Lineup of 2 models: high voltage/high accuracy and standard Isolated multi-channel data logger midi LOGGER GL840 series-Part Number-GL840-M

GL840-M

Available upon quote ⊿Σ method, 16Bit (effective resolution: ±1/40,000 of range) AC100~240V/50~60Hz Standard terminal, high voltage high precision terminal, screwless terminal (optional) Up to 2 DC7.2V (2,900mAh) can be installed (battery pack option) GL840-M/WV: Approx. 8GB (built-in fixed) GL840-SDM/SDWV: Approx. 8GB (SD memory card included, can be removed from slot) DC8.5~24V Size 7 inch TFT color LCD (WVGA: 800 x 480 dots) Japanese, English, French, German, Chinese, Korean, Russian, Spanish Waveform + digital screen, all waveform screen, digital + calculation screen, enlarged digital screen, integrated bar graph screen GL840-M: 240×158×52.5mm GL840-WV: 240×158×52.5mm (high voltage terminal block included) 1ch trigger input or 1ch external sample input,
4ch logic input or 4ch pulse input
Maximum input frequency: 50kHz
Maximum count: 50kC/sampling
SD2 slot: SDHC compatible, up to approximately 32GB memory usable (cannot be used when wireless LAN unit (B-568) is installed.) Alarm output 4ch GL840-M: 1,010g GL840-WV: 1,035g 1 unit (20ch) or expansion unit (maximum 200ch) Ethernet (10BASE-T/100BASE-TX), USB2.0, Wireless LAN (Option: B-568 required) GBD/CSV format (data recorded with GL840 only) 38VA or less (using AC adapter, LCD ON, battery pack charging, AC100V) OFF/Ring recording/Relay recording
・Ring recording: When the number of recorded points is exceeded, data is recorded while deleting old data.
・Relay recording: Separate files into 2GB units and record continuously without missing any data.
10ms~1h (10~50ms is voltage only, limited number of channels), external 0~45℃, 5~85%RH (0~40℃ when running on battery/15~35℃ when charging) Equivalent to Automotive Parts Class 1 Class A