Product
Ultrasonic thickness meter with A-scope display provides reliable wall thickness measurement DMS GoHandling Company
Shinmei General Co., Ltd.Categories
Product Image | Part Number | Price (excluding tax) | Applicable standards EMC/EMI | Attached | Battery | Calibration mode | Compatible standards Ultrasound | Data recorder | Display language | Display resolution | Display section | Dustproof/Splashproof | External dimensions | File format | I/O connector Others | I/O connector probe | Impact resistance | Measured value display | Measurement method | Measuring range | Memory | Operating temperature | Parsa | Receiver | Screen pixels | Screen size | Sound speed range | Storage temperature | Unit of measurement | Update rate | Vibration resistance | Weight |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DMS Go+ Basic |
$ 3,828.50〜 | EN 55011&EN61000-6-2:2001 |
2×2 ~ 9×9 microgrids can be inserted per measurement point 1 to 16 comments can be attached to one file (up to 16 alphanumeric characters per measurement point) A scope display or B scope display |
Lithium-ion battery (remaining capacity can be checked) |
1-point calibration (automatic, zero block, manual) 2 point calibration Automatic V-path correction |
EN 15317, EN12668, ASTM-E1324, ASTM-E317 |
Approximately 100,000 measurements per file SD card can store multiple files |
Japanese, English, Chinese, etc. | 0.01mm or 0.1mm | WVGA color LCD (with LED backlight) |
IEC 529 Specification for IP67 Classification |
111×175×50mm (H×W×D) | Linear, Grid, Boiler, Custom Linear, Custom Grid, Advanced (3D, 4D) | Mini USB, power connector | Remo 00×2 |
M6 cycles each Axis, 15 g, 11 ms Half Sine, MIL-STD-810E Method 516.5, Procedure I |
A scope Thickness measurement value + A scope B scope + thickness measurement Min/Max Differential thickness measurement (% or mm) |
Zero cross measurement/R-B1, B1-Bn, S-B1 method DMS Go TC/Advanced only: TOPCOAT (Patent # 6,035,717) and AUTO-V |
0.40mm~650mm (medium steel) (Depending on the material and surface condition of the probe and test piece) |
2GB SD card (Up to 16GB memory card can be used) |
0℃~+55℃ |
Square pulse, pulse width and voltage automatic adjustment |
110dB dynamic range Gain automatic adjustment/user setting: High, low, automatic |
480×800 pixels (H×W) | 64.8×100mm (H×W) | 250~16,000m/s |
-20℃~+60℃ (24 hours including battery) |
Mm or inch (switchable) |
32Hz (minimum/maximum display mode, B scope mode) 4Hz, 8Hz, 16Hz (standard mode) |
MIL-STD-810E method 514.5, Procedure I, Annex C, Figure 6, General Exposure: 1 hr each Axis |
870g (Including battery) |