■Summary

The Exicor MicroImager developed by HINDS is a state-of-the-art device that automatically measures the retardation and fast axis caused by birefringence of a sample with high spatial resolution and high precision. Image measurement is achieved using a high-pixel CCD camera based on polarization measurement using a photoelastic modulator (PEM). When using a 5x objective lens, the field of view is 2.2 mm square and the spatial resolution is 2 µm. It enables quantitative evaluation of minute birefringence distributions that are difficult to observe with conventional polarizing microscopes. It is also possible to measure at multiple wavelengths and measure high-order phase differences.

■High measurement performance

Achieving retardation resolution of 0.01nm and noise floor of 0.2nm, it is possible to measure industrial materials with low distortion. Furthermore, by adopting a high-resolution CCD camera with 4M pixels, it is possible to clearly capture complex birefringence distributions such as in biological samples. The measurement wavelength can be switched between 4 wavelengths: 450nm, 530nm, 590nm, and 630nm, making it possible to not only measure at a wavelength suitable for the sample, but also to measure high-order birefringence. You can also switch between two lighting systems. Kohler illumination is suitable for applications that require spatial resolution, such as biological samples, and parallel light illumination is suitable for industrial products that require quantification performance. All measurements are automatically controlled by software and are easy to handle.

■Customizable

The Exicor MicroImager's hardware and software are designed by HINDS. We support customization such as custom-made stages and various polarization analyses.

■Measurement example

It is possible to visualize strain distribution in industrial materials and biological samples.

■Main uses

・Visualization of various biological samples ・Evaluation of optical elements ・Birefringence distribution of three primary color filters ・Visualization of internal stress distribution ・Evaluation of resin flow direction and stress of injection molded products ・Visualization of crystal structure

■Measurement image size/resolution

・5,600 × 5,600μm, resolution 5μm (2x objective lens) ・2,200 × 2,200μm, resolution 2μm (5x objective lens) ・1,000 × 1,000μm, resolution 1μm (10x objective lens) ・500 × 500μm, resolution 0.5μm (20x objective lens)

  • Product

    Exicor MicroImager, a microbirefringence imaging system specialized for small areas within the sample plane, high spatial resolution of 2 μm, and RGB wavelength switching.

Share this product


20+ people viewing

Last viewed: 3 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

1 Models of Exicor MicroImager, a microbirefringence imaging system specialized for small areas within the sample plane, high spatial resolution of 2 μm, and RGB wavelength switching.

Image Part Number Price (excluding tax) Microscope Fast axis resolution Sample stage movement amount Illumination optical system Measurement time Measurement center wavelength (select multiple from 4 wavelengths) Measurement parameters Body size Retardation repeatability (3σ) Retardation measurement range Retardation resolution CCD camera
Exicor MicroImager, a microbirefringence imaging system specialized for small areas within the sample plane, high spatial resolution of 2 μm, and RGB wavelength switching.-Part Number-Exicor MicroImager

Exicor MicroImager

Available upon quote

Dedicated microscope developed by HINDS

0.5 degrees

75×56mm

Pseudo kohler illumination
pseudo parallel light illumination

Approximately 7 seconds (standard)

B: 450nm
G: 530nm
A: 590nm
R: 630nm

Retardation, fast axis direction

30.5 × 25.4 × 68.5 (H)

0.6nm or less

0.1nm~300nm or more (half wavelength or less of measurement wavelength)
High-order measurement possible with multiple wavelength measurements (phase connection processing)
-RGB: about 2,400nm
-RAGB: 3,500nm or more

0.01nm

2,048 × 2,048 pixels, 12 bit

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Polarizing Microscopes Products

Other products of Tokyo Instruments, Inc

Reviews shown here are reviews of companies.


View more products of Tokyo Instruments, Inc

About Company Handling This Product

Response Rate

100.0%


Response Time

36.5hrs

Company Overview

Tokyo Instruments, Inc., established in 1981, and headquartered in Tokyo, Japan, is a manufacturer of opto-ele...

See More

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree