Optical quantum sensor 370-650nm SDI-12 output SE-SQ-421X-SSHandling Company
Senecom Co., Ltd.Image | Part Number | Price (excluding tax) | Nonlinearity | Power supply | Weight | Viewing angle | Measuring range | Current consumption | Wavelength range | Calibration factor | Response speed | Response temperature | Operating environment | Output | Reproducibility | Specification | Drift value | Sensor dimensions | Cosine correction | Option |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
SE-SQ-421X-SS |
Available upon quote |
Less than 1% (up to 4,000µmol m⁻²sˉ¹) |
5.5~24VDC |
Includes 5m of 140g cable |
180° |
0~4,000µmol m⁻²sˉ¹ |
1.8mA when operating, 1.4mA when stationary |
370~650nm (response wavelength ≧50%) |
Firmware settings |
Less than 0.6s |
-0.04%/℃ |
Temperature -10~+60℃, relative humidity 0~100%, water depth up to 30m |
SDI-12 |
Less than 0.5% |
Detachable connector cable |
Less than 2%/year |
30.5mm×37mm |
75°zenith angle ±5% |
Sensor fixing base, sensor support rod, sensor mounting bracket |