All Categories
History
Response Rate
100.0%
Response Time
12.6hours
Relatively Fast Response
Product
Visibility meter forward scatter method SE-SWS-200Handling Company
Senecom Co., Ltd.Image | Part Number | Price (excluding tax) | Snowfall resolution | Precipitation resolution | Measurement area | Visibility measurement accuracy | Visibility measurement range (MOR) | Power consumption | Maximum precipitation | Dimensions/weight | Operating power supply | Resolution | Output interval | Food heater power supply | Digital output | Analog output (visibility MOR) | Option |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
SE-SWS-200 |
Available upon quote |
0.0015mm/h |
0.015mm/h |
39°~51° (forward scatter) |
MOR~10km |
0m~20km (standard) |
3.5W normal (36W heater ON) |
500mm/h |
0.81m/4.0kg |
9~36VDC |
1m or 10m (standard) |
10~300 seconds |
24V AC/DC |
RS232, RS422/RS485 |
0~10V (option: 0~20mA or 4~20mA) |
RVR (Runway Visual Range) parts, calibration kit, sensor storage box, power adapter, power cable, signal cable |
Reviews shown here are reviews of companies.
Response Rate
100.0%
Response Time
12.6hrs