Product
Composite Weather Sensor WS401-UMB Weather PackHandling Company
Senecom Co., Ltd.Categories
Product Image | Part Number | Price (excluding tax) | Atmospheric pressure | Cable length | Current consumption Power saving mode | Current consumption Standard mode | Dew point temperature | Dimensions/weight | Drip-proof standard | Falling Rainfall | Humidity | Interface | Mounting pole size | Option | Power supply | Temperature | Temperature measurement range |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SE-WS401-UMB |
Available upon quote |
Sensor: MEMS electrostatic type Measurement range: 300~1,200hPa Resolution: 0.1hpa Accuracy: ±0.5hPa (0~+40℃) Sampling rate: 1 minute Unit: hPa |
Standard 10m cable |
12V: 25mA 24V: 16mA |
12V: 65mA without heater 24V: 130mA without heater |
Measurement range: -50~+60℃ Resolution: 0.1℃ Accuracy: Calculated value ±0.7℃ Unit: ℃, ℉ |
164mmφ×H380mm/1.5kg | IP66 |
0-359.9° (instantaneous/maximum/vector average) Sampling rate: 10 seconds Error range: Wind speed is 1.0m/s, <3°RSME>1.0m/s Resolution: 0.1° Unit: ° |
Sensor: Capacitive Measurement range: 0~100%RH Accuracy: ±2%RH Resolution: 0.1%RH Sampling rate: 1 minute Unit: %RH, g/m3-, g/kg |
Lufft compatible protocol: RS485 UMB-Binary Others: UMB-ASCII, Modbus-RTU, ModbusASCII, XDR and SDI-12 |
Φ60~76mm | Senecom Japanese software/RS485-232C converter USB cable included, analog converter DACON8-UMB | DC12V/24V |
Sensor: NTC Accuracy: ±0.2° (-20~+50°C), otherwise ±0.5°C (>-30°) -30 Resolution: 0.1℃ (-20~+50℃), otherwise 0.2℃ Sampling rate: 1 minute Unit: ℃, ℉ |
-50~60℃ |