All Categories

History

Our long-selling product, the spectroradiometer SR-3AR, has been established as an industry standard since the early days of LCD displays.-SR-3AR
Our long-selling product, the spectroradiometer SR-3AR, has been established as an industry standard since the early days of LCD displays.-Irie Co., Ltd.

Our long-selling product, the spectroradiometer SR-3AR, has been established as an industry standard since the early days of LCD displays.
Irie Co., Ltd.

Irie Co., Ltd.'s Response Status

Response Rate

100.0%

Response Time

14.2hours

Relatively Fast Response


About This Product

■Product overview

Nowadays, as the performance and quality of displays continues to improve, the measurement standards required of measuring instruments are becoming even more sophisticated. SR-3AR is a long-selling product of our company that meets a wide range of customer needs. We have improved the SR-3A/SR-3A-L1, which has been well received for many years, to expand the measurement range, achieve more stable measurement, and dramatically improve operability.

■Features

・High absolute value accuracy due to spectrophotometric method ・Supports measurement from 0.1cd/m² ・Highly accurate measurement of low brightness areas on microscopic surfaces without an attachment lens ・Highly accurate measurement of frequency lighting light sources (equipped with synchronous measurement function and integral time delay function) ・A wealth of data processing and main unit control are possible with standard application software.

■Main uses

・General evaluation of optical characteristics such as brightness, chromaticity, temperature characteristics, contrast measurement, light distribution characteristics, etc. of displays, lighting, etc. ・High-precision measurement of brightness and chromaticity of minute surfaces such as automobile instrument panels, audio, operation panels, etc. ・Evaluation of light quality of other traffic signs, traffic lights, various special light sources, etc.

■Optional accessories

・Attachment lens AL-6 ・Attachment lens AL-11 ・Attachment lens AL-12 ・Standard white board WS-3 ・CCD adapter IA-2 ・Fiber probe FP-3P ・ND filter ND-10/100 ・Tripod Tripod 5N type ・Tripod Tripod-SR ・Fine movement table S-4 ・Illuminance adapter ZV-30

  • Product

    Our long-selling product, the spectroradiometer SR-3AR, has been established as an industry standard since the early days of LCD displays.

Share this product


70+ people viewing

Last viewed: 19 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

1 Models of Our long-selling product, the spectroradiometer SR-3AR, has been established as an industry standard since the early days of LCD displays.

Image Part Number Price (excluding tax) Power supply Brightness accuracy Brightness measurement range Mass Chromaticity accuracy (x,y) Repeatability Brightness Repeatability Chromaticity Calculation content Measurement distance Measurement angle Measurement wavelength range Measurement time Measurement details Measurement mode Power consumption Wavelength accuracy Wavelength resolution Wavelength dispersion element External dimensions (W×D×H) Photodetector Optical system Polarization properties Terms of use Spectral wavelength width Interface
Our long-selling product, the spectroradiometer SR-3AR, has been established as an industry standard since the early days of LCD displays.-Part Number-SR-3AR

SR-3AR

Available upon quote

Dedicated AC adapter AC100~240V (50/60Hz)

Within ±2%

2.0° 0.1~3,000, 1.0° 0.3~9,000 0.2° 7.5~70,000, 0.1° 30~300,000

5.5kg

±0.002

0.3% 0.1 cd/m² or more

0.0005 0.1 cd/m² or more

Radiance Le W・sr-1・m-2, luminance Lv cd・m-2 CIE1931 chromaticity coordinate xy, CIE1976 chromaticity coordinate u'v' tristimulus value XYZ, correlated color temperature (Tc;k), deviation ( duv) and others

350mm~∞ (distance from the tip of the objective lens hardware)

2°/1°/0.2°/0.1° *Electric switching type

380~780nm

NORMAL mode approximately 1~31 seconds, HIGH SPEED mode approximately 1~17 seconds

Spectral radiance W・sr-1・m-2・nm-1

Auto/manual (storage time/frequency), external vertical synchronization signal input

Approximately 34W

±0.3nm *In Hg emission line

1nm

Diffraction grating

150×406×239mm

Electronically cooled linear array sensor

Objective lens f=82mm F2.5, eyepiece observation field of view 5°

Luminance 1% or less, spectral radiance 2% or less (400~780nm)

Temperature 5~35℃, humidity 80%RH or less, non-condensing

5~8nm (half width)

RS-232C, USB 2.0

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Spectroradiometers Products

Other products of Irie Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Irie Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

14.2hrs


Company Review

4.8
  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree