Cutting-edge waste heat utilization waste heat input type absorption chiller/heater Efficio Genelink NZJ type NZJ-250 (gas fired)-NZJ-250
Cutting-edge waste heat utilization waste heat input type absorption chiller/heater Efficio Genelink NZJ type NZJ-250 (gas fired)-Kawaju Refrigeration Industry Co., Ltd.

Cutting-edge waste heat utilization waste heat input type absorption chiller/heater Efficio Genelink NZJ type NZJ-250 (gas fired)
Kawaju Refrigeration Industry Co., Ltd.


About This Product

Features of absorption chiller/heater/freezer

■Diverse thermal energy use

In addition to fuels (gas, oil), various types of thermal energy can be used, such as waste heat from gas engines, steam, and natural solar heat.

■Peak cut

Since thermal energy is the main power, electricity consumption during operation is small. In general, the amount of electricity used for air conditioning tends to increase in the summer, but since absorption chiller/heaters and refrigerators consume less electricity, it is possible to cut peak electricity consumption in the summer.

■Gas/oil switching exclusive firing

Since it can use stockpiled fossil fuels, it can also be used as a BCP measure for hospitals and public facilities that need to operate even in the event of a disaster. Product overview

■Pursuit of energy saving

Based on the highest standard Efficio series, we incorporate a unique waste water heat exchanger to reduce costs and reduce environmental impact. Rated fuel consumption is further reduced by 41% compared to the base machine. (NZJ type)

■Fuelless operation up to 60% load factor

Equipped with an optional waste hot water standalone operation mode that does not use fuel except during startup. In normal mode, it is possible to operate with only waste hot water and zero fuel up to a load factor of 60%.

■Realization of weight reduction. Lineup of power saving type and waste hot water increasing type

Thanks to the small, high-performance heat exchanger incorporated in the Efficio series and detailed optimization, we have achieved a weight reduction of 20% (30% for the NHJ type) compared to the previous model. It is possible to reduce delivery costs and reinforcement costs for existing foundations during renewal plans. The lineup includes models that increase the flow rate of waste hot water, which can be selected according to the waste heat amount of the cogeneration equipment. We also propose specifications that best meet customer needs, such as energy-saving models that are ideal for peak cuts in the summer.

  • Product

    Cutting-edge waste heat utilization waste heat input type absorption chiller/heater Efficio Genelink NZJ type NZJ-250 (gas fired)

Share this product


30+ people viewing

Last viewed: 13 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

1 Models of Cutting-edge waste heat utilization waste heat input type absorption chiller/heater Efficio Genelink NZJ type NZJ-250 (gas fired)

Image Part Number Price (excluding tax) High temperature absorption liquid pump (50Hz/60Hz) kW Power supply current (50Hz/60Hz) A Power capacity (50Hz/60Hz) kVA Electricity power supply Total motor output (50Hz/60Hz) kW Wiring thickness (50Hz/60Hz) mm2 Capacity Heating kW (Mcal/h) Capacity Cooling Maximum waste heat recovery kW (USRT) Capacity Cooling kW (USRT) Fuel consumption Heating (without waste heat recovery) m3N/h (kW) Fuel consumption When cooling (without waste heat recovery) m3N/h (kW) Fuel consumption When cooling (with waste heat recovery) m3N/h (kW) Hot water inlet temperature - outlet temperature °C Spray absorption liquid pump (50Hz/60Hz) kW Required supply pressure kPa Waste heat recovery amount kW (Mcal/h) Waste hot water flow rate m3/h Waste hot water pressure loss kPa Waste hot water inlet temperature - outlet temperature °C Amount of waste hot water held m3 Cold and hot water flow m3/h Cold and hot water pressure loss kPa Amount of cold and hot water held m3 Chilled water inlet temperature - outlet temperature °C Refrigerant pump (50Hz/60Hz) kW Cooling water flow rate m3/h Cooling water pressure loss kPa Cooling water inlet temperature - outlet temperature °C Cooling water capacity m3 Low temperature absorption liquid pump (50Hz/60Hz) kW
Cutting-edge waste heat utilization waste heat input type absorption chiller/heater Efficio Genelink NZJ type NZJ-250 (gas fired)-Part Number-NZJ-250

NZJ-250

Available upon quote

0.55/0.55

33.1/30.7

10.6/9.8

200V, 3Φ

5.1/5.1

8.0/8.0

586 (504)

527 (150)

879 (250)

13A gas
52.1 (651)

13A gas
52.1 (651)

13A gas
30.6 (382)

54.7 → 60.0

1.3/1.3

1.96

451 (388)

40

51.9

90.0 → 80.0

0.13

94.5

79.3

0.36

15.0 → 7.0

0.3/0.3

250

71

32.0 → 37.8

0.84

2.2/2.2

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More HVACs Products

Other products of Kawaju Refrigeration Industry Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Kawaju Refrigeration Industry Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree