Temporary DC power supply for maintenance FKT25W-ⅢHandling Company
Fuji Electric Co., Ltd.Categories
Image | Part Number | Price (excluding tax) | Mass | Evaluation noise | Setting voltage accuracy | Insulation voltage | Maximum output current | Maximum output voltage | Frequency | Efficiency | Output current adjustment range | Output voltage adjustment range | Cooling method | Input power | Operating ambient temperature | AC input | Ripple voltage | Ripple noise |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FKT25W-Ⅲ |
Available upon quote |
Approximately 22kg |
5mV or less |
Within ±2% |
Input-output AC1,500V for 1 minute DC500V 10MΩ or more |
50A |
DC60V (switchable) |
45~65Hz |
85%TYP |
0~50A (stepless continuous) |
DC22V~60V (stepless continuous) |
Forced air cooling |
11A TYP |
-10℃~50℃ |
3φ AC180V~220V |
MAX300mV (P-P) |