Freon gas leak prevention Freon gas alarm (embedded type)Handling Company
A-Gas Japan Co., Ltd.Categories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Power supply voltage | Alarm sound | Alarm concentration (detectable concentration) | Call delay (responsiveness) | Gas to be detected | External output terminal | Product name/model | Operating temperature and humidity range | Sensor | Abnormal alarm buzzer stop function | Power consumption | Standard accessories | Body external dimensions (mm) / mass (g) | Installation method | Initial ringing prevention | Storage temperature and humidity range |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FU-8F-410A |
$ 312.00〜 |
AC100V (±10%) 50/60Hz |
Intermittent electronic sound 70dB (measured from 1m away) |
1,000ppm ~ 4,000ppm (at factory shipment) and 1/2 RCL or less (RCL = Refrigerant limit concentration in a closed space) Japan Refrigeration and Air Conditioning Industry Association Guidelines JRA GL-13 Standard |
Within 30 seconds with 1.6 times gas of 1/2RCL |
R410A |
C contact x 1, A contact x 1 (AC250V DC30V 1A with resistive load) |
Freon gas alarm/FU − 8F |
Temperature: -10℃~50℃, Humidity: 80% RH or less (no condensation) |
Semiconductor type fluorocarbon sensor |
The alarm buzzer in the event of an abnormality can be stopped by pressing and holding RESET-SW. However, the red lamp will not go out until the concentration drops. |
6W or less |
Instruction manual (with warranty), construction manual |
Main body: W116 x H120 x D36.5 / approx. 240 |
Attached to 2-port switch box |
No alarm will be issued for the first 3 minutes when the power is turned on. |
Temperature: 0℃~40℃, Humidity: 80% RH or less (no condensation) |
|
FU-10F |
$ 312.00〜 |
AC100V ± 10% 50/60Hz |
Electronic sound 70dB |
1/2 RCL or less (RCL= Refrigerant limit concentration in a closed space) (One company) Japan Refrigeration and Air Conditioning Industry Association Guidelines JRA GL-13 Standard |
Within 30 seconds with 1.6 times gas of 1/2RCL |
R22, R32, R134a, R404A, R407C, R410A |
Gas alarm and failure alarm contact: 1c no-voltage contact/automatic reset, rated load AC250V 1A or DC30V 1A resistive load |
Freon gas alarm/FU-10F |
Temperature: -10 ~ +50℃, Humidity: 10 ~ 85%RH (below 40℃, do not exceed the absolute humidity of 40℃ 85%RH. (If at 50℃ |
Hot wire semiconductor sensor |
- | - | - | - | - | - | - |