All Categories

History

Handheld real-time spectrum analyzer (9kHz to 50GHz) 4024H-4024H
Handheld real-time spectrum analyzer (9kHz to 50GHz) 4024H-T&M Corporation Co., Ltd.

Handheld real-time spectrum analyzer (9kHz to 50GHz) 4024H
T&M Corporation Co., Ltd.

T&M Corporation Co., Ltd.'s Response Status

Response Rate

100.0%

Response Time

28.1hours

Relatively Fast Response


About This Product

■Main features

・Frequency range: 9 kHz to 67 GHz, 9 models ・Low display average noise level: -163dBm@1Hz RBW (typical value) ・Excellent phase noise performance: -112dBc/Hz@100kHz frequency offset@1GHz carrier (4024A/B/C) -106dBc/Hz@100kHz frequency offset@1GHz carrier (4024D/E/F/G/H/L) ・High sweep speed: Minimum sweep time <20ms for 1GHz span ・Resolution bandwidth: 1Hz to 10MHz ・All band preamplifier: Standard configuration ・Various measurement functions: Spectrum analyzer, interference analyzer (spectrogram, RSSI), AM/FM/ PM analyzer, channel scanner, high precision power meter, signal analyzer, etc.・Various intelligent measurement functions: Field strength measurement, channel power, occupied bandwidth, adjacent channel power ratio, tune & listen, carrier to noise ratio, emission mask and various auxiliary test interfaces: 10MHz reference input/output interface, GPS antenna interface, zero span IF output interface, external Trigger input interface etc.

■SSB phase noise (carrier 1GHz)

・≤-102dBc/Hz@Frequency offset 10kHz ・≤-106dBc/Hz@Frequency offset 100kHz ・≤-111dBc/Hz@Frequency offset 1MHz ・≤-123dBc/Hz@Frequency offset 10MHz

  • Product

    Handheld real-time spectrum analyzer (9kHz to 50GHz) 4024H

Share this product


110+ people viewing


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

1 Models of Handheld real-time spectrum analyzer (9kHz to 50GHz) 4024H

Image Part Number Price (excluding tax) Electromagnetic compatibility Weight (without batteries) Absolute amplitude accuracy External dimensions Reference level Frequency readout accuracy Frequency range Frequency reference Operating temperature Overall power consumption (not including battery charging) Input attenuator Storage temperature Second harmonic distortion (attenuation 0dB, -30dBm input) Battery run time Test port Span width Scan time Other interfaces
Handheld real-time spectrum analyzer (9kHz to 50GHz) 4024H-Part Number-4024H

4024H

Available upon quote

Compliant with the requirements of 3.9.1 of GJB3947A-2009

≤5.3kg

±1.8dB (10MHz~13GHz)
±2.3dB (13GHz~40GHz)
±2.7dB (40GHz~50GHz)
±3.0dB (50GHz~67GHz)

314mm (width) x 218mm (height) x 91mm (depth) (excluding handle and stand)
338mm (width) x 218mm (height) x 100mm (depth) (including handle and stand)

Range: -120dBm~+30dBm
Conversion uncertainty: ±1.20dB

± (Frequency readout x Frequency reference error +2% x Span +10% x Resolution bandwidth)

9kHz~50GHz

Frequency: 10MHz
Aging rate: ±0.5ppm/year
Initial frequency accuracy: ±0.3ppm
Temperature stability: ±0.1ppm (-10~50℃, compared to 25℃)

-10℃~+50℃ (Battery operating temperature is 0℃~+45℃)

≤38W

+27dBm peak (typical) (≥10dB attenuation)
+20dBm peak (typical) (<10dB attenuation)
+10dBm peak (typical) (preamp on)

-40℃~+70℃ (Battery storage temperature is -20℃~+60℃)

<-65dBc

Approximately 2 hours (standard)

RF input: 1.85mm connector (male)

Range: 100Hz ~ upper limit frequency of compatible model, or 0Hz
Accuracy: ±2.0%
Resolution bandwidth: 1Hz~10MHz (1~3x steps)
Video bandwidth: 1Hz~10MHz (1~3x steps)

Range: 10μs~600s (zero span)
Accuracy: ±2.00% (zero span)

10MHz reference input/output: BNC (female) connector
External trigger input: BNC (female) connector
IF output: BNC (female) connector
GPS antenna input: BNC (female) connector

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Spectrum Analyzers Products

Other products of T&M Corporation Co., Ltd.