Product
Metric tape type liquid level gauge (for industrial use)Handling Company
CBSI CorporationCategories
Product Image | Part Number | Price (excluding tax) | Applicable temperature (℃) | Effect of specific gravity | Explosion-proof | Filter life | Filter material | Housing dimensions | Housing material | Installation | Measuring range | Operation start point (in case of water) | Outer jacket | Power consumption | Protection tube | Protector | Purpose*1 | Resistance value | Resolution | Sensor total length | Sensor width | Tank pressure | Temperature detection (optional) | Weight (total equipment) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
L.A. |
Available upon quote | -15~+60 | For a 1% increase in specific gravity, the indicator will increase by 1.5 to 1.8 mm (Cancellation of specific gravity is possible when adjusting the scale.) | Intrinsically safe explosion-proof (when equipped with barrier) | Around 4 years (depending on installation environment) | Mainly uses polypropylene | 235x184 (mm) | SUS304 or SUS316 | JIS 10K 80A flange | Length excluding upper (220mm) and lower (37mm) dead zones | LA: 145mm, LA-HN/LA-HP: 180mm | Mylar | 500mW |
Basically, installation is required, but in some cases it is not necessary if a weight is attached to the end of the measurement sensor. However, if there are ripples, bubbles, or floating objects on the liquid surface, it is necessary to install a protection tube. |
Polypropylene |
Water and sewage, river water, seawater, drainage *1 There is a corrosion resistance table for each liquid, please check with the manufacturer for further details. |
1,000Ω/m | ±3mm | 914mm~36m | 35mm | Approximately ±100kPa can be used | Up to 3 points, 0.6m or more from the bottom of the sensor, midpoint, 3m or less from the top | 10kg+0.6kg/m |