All Categories
History
                                        
                                Product
Linear amplifier DC/AC servo driver LPV series LPV120Handling Company
Servo Techno Co., Ltd.Categories
| Image | Part Number | Price (excluding tax) | Current frequency response | Power control method | Weight | Speed, position control command input | Function indicator lamp | Function Output signal | Function Input signal | Function Protection function | Maximum output | Power supply for operation signals | Command input | Rated output | External dimensions (W×D×H) | Control power supply | Control method | Control loop | Storage temperature, humidity | Operating temperature and humidity | Positioning | Main power supply | Main circuit | Encoder input | Power supply for encoder signal output | 
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
                                                                                                 
                                                                                     | 
                        
                            LPV120 | 
                        Available upon quote | 
                                                                                                             
 
                                            DC~20KHz or more  | 
                                                    
                                                                                                             
 Linear amplifier  | 
                                                    
                                                                                                             
 0.2Kg  | 
                                                    
                                                                                                             
 
                                            Pulse train  | 
                                                    
                                                                                                             
 
                                            Overcurrent trip (CUR), high temperature abnormality (TMP),  | 
                                                    
                                                                                                             
 
                                            Alarm (over high temperature, overcurrent trip, full count)  | 
                                                    
                                                                                                             
 
                                            Servo on, reset,  | 
                                                    
                                                                                                             
 
                                            Overcurrent, overvoltage,  | 
                                                    
                                                                                                             
 
                                            Voltage ±Vmax16  | 
                                                    
                                                                                                             
 
                                            No need  | 
                                                    
                                                                                                             
 
                                            ±10V  | 
                                                    
                                                                                                             
 
                                            Voltage ±Vmax20  | 
                                                    
                                                                                                             
 112×120×35mm  | 
                                                    
                                                                                                             
 #ERROR!  | 
                                                    
                                                                                                             
 
                                            Deviation due to PLL (Phase-Locked Loop) method  | 
                                                    
                                                                                                             
 
                                            Current control  | 
                                                    
                                                                                                             
 
                                            Temperature: -20~+50℃  | 
                                                    
                                                                                                             
 
                                            Temperature: 0~+40℃  | 
                                                    
                                                                                                             
 
                                            ±1 pulse  | 
                                                    
                                                                                                             
 ±12V  | 
                                                    
                                                                                                             
 BTL (BridgedTransless) connection  | 
                                                    
                                                                                                             
 
                                            2 phase incremental encoder  | 
                                                    
                                                                                                             
 
                                            Common with control power supply  | 
                                            
Reviews shown here are reviews of companies.