High -speed automatic scan IntellitRax2 (Intellit Lux 2)-Den City Model
High -speed automatic scan IntellitRax2 (Intellit Lux 2)-X -Light

High -speed automatic scan IntellitRax2 (Intellit Lux 2)
X -Light

X -Light's Response Status

Response Rate

100.0%

Response Time

5.1hours

Very Fast Response


About This Product

High -speed automatic scanning of color bars by simple operation of measurement button one push. Supports printing standardization.

■ Easy operation

Daily operation is completed with one touch

■ High -speed scan speed

High -speed and accurate measurement technology with DRS branches Automatically track color bars by introducing NCIS (look -ahead sensor)

■ Easy -to -understand graphic display

Graphic display that shows the problems with the public

■ M1 compatible (M0/M1 simultaneous measurement)

■ Stable measurement accuracy by adsorption by vacuum pump

■ There is no worry about dirt due to ink for non -contact measurement

■ Abundant options

You can select track size and measurement size Select of concentration type and spectroscopy type 2mm and 3mm measurement size can be selected

■ Compatible with the standard print authentication standard of JAPAN COLOR, new FOGRA and G7 (spectrum model)


  • Product

    High -speed automatic scan IntellitRax2 (Intellit Lux 2)

Share this product


260+ people viewing

Last viewed: 30 minutes ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

2 Models of High -speed automatic scan IntellitRax2 (Intellit Lux 2)

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Optical geometric conditions Spectroscopy system Spectroscopy range Measuring mode Spectroscopy resolution Measurement speed The smallest patch size that can be read (height x width) Maximum paper thickness Track width * (maximum paper width) Color bar reading range Concentration range Short -term repetition accuracy Characterized short -term repetition accuracy Gear Number of units (number of colors) Concentration function Report function Concentration status Blank paper standard concentration Double -sided printing machine compatible Footpo dal Color function Coloring function Best match Illuminant (light source) Standard observer (visual angle) Print standard support Custom chart measurement NetProfiler Pantonelive
High -speed automatic scan IntellitRax2 (Intellit Lux 2)-Part Number-Den City Model

Den City Model

Available upon quote

45 ° / 0 ° ring placement lighting, ISO 5-4: 2009 (E)

DRS (Dynamic Rotation Sampling) 31 points

400nm-700nm

ISO13655 2009 compliant M0: Non -polarized, No filter, UV including / M1: D50 / M3 (optional) / Polarized filter

Measurement: 10nm output: 10nm

170mm / second

Small spots: 2.0mm x 3.0mm medium medium spots: 3.0mm x 3.0mm polarized model: 3.0mm x 3.0mm

1.0mm

29 inches (840mm) / 32 inches (910mm) / 40 inches (1,115mm) / 44 inches (1,215mm) / 56 inches (1,430mm) / 65 inches (1,700mm)

Within 38mm from the paper edge (the position of the color bar is automatically recognized)

0-3.0D

0.15 Δ E76 MAX White

± 0.01D MAX White ± 0.02D @1.8d Cyan, Magenta, Black ± 0.02D @2.0D (M3: ± 0.03D @1.8d) Yellow

0.30 δ E76 Average 0.45 δ E76 (M3: 0.55 Δ E76) Up to 12 colors BCRA color tiles and BCRA White Reference Temperature: 23 ° C ± 1 ° C, humidity of 40-60% RH Escembly conditioner: D50 / 2 °

Up to 8 colors for the front and back

Capacity / Dot Gain (TVi) / Trapping / Contrast / Gray Balance

A / E / I / T / HIFI / HEXACHROME / EX / TXP

Absolute concentration / blank paper standard concentration

option

- - - - - - - - -
High -speed automatic scan IntellitRax2 (Intellit Lux 2)-Part Number-Spectrum model

Spectrum model

Available upon quote

45 ° / 0 ° ring placement lighting, ISO 5-4: 2009 (E)

DRS (Dynamic Rotation Sampling) 31 points

400nm-700nm

ISO13655 2009 compliant M0: Non -polarized, No filter, UV including / M1: D50 / M3 (optional) / Polarized filter

Measurement: 10nm output: 10nm

170mm / second

Small spots: 2.0mm x 3.0mm medium medium spots: 3.0mm x 3.0mm polarized model: 3.0mm x 3.0mm

1.0mm

29 inches (840mm) / 32 inches (910mm) / 40 inches (1,115mm) / 44 inches (1,215mm) / 56 inches (1,430mm) / 65 inches (1,700mm)

Within 38mm from the paper edge (the position of the color bar is automatically recognized)

0-3.0D

0.15 Δ E76 MAX White

± 0.01D MAX White ± 0.02D @1.8d Cyan, Magenta, Black ± 0.02D @2.0D (M3: ± 0.03D @1.8d) Yellow

0.30 δ E76 Average 0.45 δ E76 (M3: 0.55 Δ E76) Up to 12 colors BCRA color tiles and BCRA White Reference Temperature: 23 ° C ± 1 ° C, humidity of 40-60% RH Escembly conditioner: D50 / 2 °

Up to a total of 16 colors on the front and sides

Capacity / Dot Gain (TVi) / Trapping / Contrast / Gray Balance

A / E / I / T / HIFI / HEXACHROME / EX / TXP

Absolute concentration / blank paper standard concentration

option

Cielab / Cielch

Δ E76 / Δ E94 / δ E2000

A / C / D50 / D65 / D75 / F2 / F7 / F11 / F12

2 ° / 10 °

Japan color / g7 / pso / ISO12647-2

option

option

Click on the part number for more information about each product

Other products of X -Light

Reviews shown here are reviews of companies.


View more products of X -Light

About Company Handling This Product

Response Rate

100.0%


Response Time

5.1hrs

Company Overview

X-Light is a manufacturer of measurement and color technology products established in 1957 and headquartered i...

See More

  • United States of America

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree