CAN type for air conditioners Indoor/outdoor unit/heat exchanger (piping) Temperature detection/outdoor unit compressor (discharge pipe) Overheating temperature detection-Indoor/Outdoor Unit/Heat Exchanger (Piping) Temperature Detection/Outdoor Unit Compressor (Discharge Pipe) Overheating Temperature Detection
CAN type for air conditioners Indoor/outdoor unit/heat exchanger (piping) Temperature detection/outdoor unit compressor (discharge pipe) Overheating temperature detection-Oizumi Manufacturing Co., Ltd.

CAN type for air conditioners Indoor/outdoor unit/heat exchanger (piping) Temperature detection/outdoor unit compressor (discharge pipe) Overheating temperature detection
Oizumi Manufacturing Co., Ltd.


About This Product

■Features ・Insulation resistance: 100MΩ or more ・Withstand voltage: AC1,500V for 1 minute or AC1,800V for 1 second ・Can handle temperatures from -40℃ to 150℃ depending on the application. (Using cross-linked polyethylene wire) ・Detects the temperature of the heat exchanger (piping) and discharge pipe.

  • Product

    CAN type for air conditioners Indoor/outdoor unit/heat exchanger (piping) Temperature detection/outdoor unit compressor (discharge pipe) Overheating temperature detection

Share this product


60+ people viewing


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

1 Models of CAN type for air conditioners Indoor/outdoor unit/heat exchanger (piping) Temperature detection/outdoor unit compressor (discharge pipe) Overheating temperature detection

Product Image Part Number Price (excluding tax) B constant Heat dissipation constant Operating temperature range Thermal time constant Zero load resistance value
CAN type for air conditioners Indoor/outdoor unit/heat exchanger (piping) Temperature detection/outdoor unit compressor (discharge pipe) Overheating temperature detection-Part Number-Indoor/Outdoor Unit/Heat Exchanger (Piping) Temperature Detection/Outdoor Unit Compressor (Discharge Pipe) Overheating Temperature Detection

Indoor/Outdoor Unit/Heat Exchanger (Piping) Temperature Detection/Outdoor Unit Compressor (Discharge Pipe) Overheating Temperature Detection

Available upon quote B25/50: 3,950K 5.0mW/℃
(in still air)
-40℃~150℃ 10 seconds or less
(in stirring water)
R25: 10KΩ