All Categories

History

Long life, compact, seismic resistance, power-saving cold cathedic UV lamp UV-CCL-UC / 4F70 / Z
Long life, compact, seismic resistance, power-saving cold cathedic UV lamp UV-CCL-Stanley Electric

Long life, compact, seismic resistance, power-saving cold cathedic UV lamp UV-CCL
Stanley Electric


About This Product

■ Characteristics

Until now, many of the proven ultraviolet rays for industrial use have used a hot cathode (hereinafter, UV-HCL). Although the UV-HCL has a high ultraviolet strength, it was hard to use for consumer products because of its large size and short life. Stanley focuses on the eradication of ultraviolet rays, and released a cold cathedic (UV-CCL) type in 2010, which is resistant to long life, compact, earthquake-resistant, power saving, ON/OFF lighting. Due to the growing health awareness in Japan and the deterioration of air pollution, it has been adopted for air removal applications for various consumer products such as deodorizers, air conditioners, and vacuum cleaners. In addition, since it is possible to remove bacteria in the water environment, it is also adopted for water -removing bacteria such as humidifiers and aquariums.

■ Supplementary explanation regarding specifications

・ Lighting start voltage * Peak voltage of both ends when the voltage slides up and the lamp is lit. ・ Recommended transformer output * Voltage of both lamps that need to be added to satisfy the dark lighting in this specification ・ UV radiation irradiation * Measurement distance = 1m, not sealed surface is measured. ・ 254nm all radiation bundle * Calculated from JIS C7605

  • Product

    Long life, compact, seismic resistance, power-saving cold cathedic UV lamp UV-CCL

Share this product


480+ people viewing

Last viewed: 10 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

6 Models of Long life, compact, seismic resistance, power-saving cold cathedic UV lamp UV-CCL

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Dimensions: a (mm) Peak wavelength (NM) Lighting start voltage Recommended transformer output Dark lighting time Tube current Pipe voltage Pipe power UV radiation irradiation 254nm total radiation bundle UV radiation irradiation stable time Direct tube length (mm)
Long life, compact, seismic resistance, power-saving cold cathedic UV lamp UV-CCL-Part Number-UC / 4F70 / Z

UC / 4F70 / Z

Available upon quote

70

254

400max peripheral temperature 25 ° C 600max peripheral temperature 0 ° C

1,000min

After lighting for 1 minute with 1 MAX rated tube current, it lights up within 1 second at the peripheral temperature, dark, 24 hours, and after leaving 24 hours. Recommended voltage must be applied to both ends of the lamp.

10 ± 0.05

Initial 140 ± 35 END OF LIFE 240MAX

Initial 1.4

2.1 ± 0.5

0.2

60max * Time to reach 90%of ultraviolet illuminance during saturation. (25 ° C, reference value for lamp alone)

-
Long life, compact, seismic resistance, power-saving cold cathedic UV lamp UV-CCL-Part Number-UC / 4F150 / Z

UC / 4F150 / Z

Available upon quote

150

254

600max peripheral temperature 25 ° C 900max peripheral temperature 0 ° C

1,200min

After lighting for 1 minute with 1 MAX rated tube current, it lights up within 1 second at the peripheral temperature, dark, 24 hours, and after leaving 24 hours. Recommended voltage must be applied to both ends of the lamp.

15 ± 0.05

Initial 205 ± 25 End of Life 320max

Initial 3.1

6.7 ± 0.8

0.6

60max * Time to reach 90%of ultraviolet illuminance during saturation. (25 ° C, reference value for lamp alone)

-
Long life, compact, seismic resistance, power-saving cold cathedic UV lamp UV-CCL-Part Number-UC / 4F240 / Z

UC / 4F240 / Z

Available upon quote

240

254

860max peripheral temperature 25 ℃ 1,300 max peripheral temperature 0 ° C

1,500min

After lighting for 1 minute with 1 MAX rated tube current, it lights up within 1 second at the peripheral temperature, dark, 24 hours, and after leaving 24 hours. Recommended voltage must be applied to both ends of the lamp.

15 ± 0.05

Initial 320 ± 50 END OF LIFE 440max

Initial 4.7

11.4 ± 1.5

1.1

60max * Time to reach 90%of ultraviolet illuminance during saturation. (25 ° C, reference value for lamp alone)

-
Long life, compact, seismic resistance, power-saving cold cathedic UV lamp UV-CCL-Part Number-UC / 4F35V / Z

UC / 4F35V / Z

Available upon quote

35

254

550max peripheral temperature 25 ° C 800max peripheral temperature 0 ° C

1,000min

After lighting for 1 minute with 1 MAX rated tube current, it lights up within 1 second at the peripheral temperature, dark, 24 hours, and after leaving 24 hours. Recommended voltage must be applied to both ends of the lamp.

10 ± 0.05

Initial 140 ± 35 END OF LIFE 240MAX

Initial 1.4

2.0 ± 0.5

0.2

60max * Time to reach 90%of ultraviolet illuminance during saturation. (25 ° C, reference value for lamp alone)

70

Long life, compact, seismic resistance, power-saving cold cathedic UV lamp UV-CCL-Part Number-UC / 4F75V / Z

UC / 4F75V / Z

Available upon quote

75

254

600max peripheral temperature 25 ° C 900max peripheral temperature 0 ° C

1,200min

After lighting for 1 minute with 1 MAX rated tube current, it lights up within 1 second at the peripheral temperature, dark, 24 hours, and after leaving 24 hours. Recommended voltage must be applied to both ends of the lamp.

15 ± 0.05

Initial 205 ± 25 End of Life 320max

Initial 3.1

6.5 ± 0.8

0.6

60max * Time to reach 90%of ultraviolet illuminance during saturation. (25 ° C, reference value for lamp alone)

150

Long life, compact, seismic resistance, power-saving cold cathedic UV lamp UV-CCL-Part Number-UC / 4F120V / Z

UC / 4F120V / Z

Available upon quote

120

254

860max peripheral temperature 25 ℃ 1,300 max peripheral temperature 0 ° C

1,500min

After lighting for 1 minute with 1 MAX rated tube current, it lights up within 1 second at the peripheral temperature, dark, 24 hours, and after leaving 24 hours. Recommended voltage must be applied to both ends of the lamp.

15 ± 0.05

Initial 320 ± 50 END OF LIFE 440max

Initial 4.7

11.1 ± 1.5

1.1

60max * Time to reach 90%of ultraviolet illuminance during saturation. (25 ° C, reference value for lamp alone)

240

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More UV Light Source Products

Other products of Stanley Electric

Reviews shown here are reviews of companies.


View more products of Stanley Electric

About Company Handling This Product

Company Overview

Stanley Electric, established in 1920 and based in Tokyo, Japan, is a manufacturer and supplier of automotive ...

See More

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree