Product
Thyristor type power regulator Three-phase power regulator PAC36P seriesHandling Company
SHIMADENCategories
Product Image | Part Number | Price (excluding tax) | Alarm output | Applicable load | Control input | Control output range | Cooling method | Current capacity | Current limit function (optional) | External output adjustment function (optional) | Feedback function (phase control) | Insulation resistance | Mass () is with heatsink | Operating temperature range | Output current detection | Output limit function at startup | Power supply voltage | Protection function | Soft start function | Withstand voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
PAC36P |
Available upon quote | 1C 250V AC 1A system and insulation overcurrent, fans, fuses, etc. | Resistive load, inductive load | 4~20mA, 0~10V, 1~5V DC, contact, etc. | 0~98% or more | 20~135A: Natural cooling type, 180~600A: Wind cooling type | 20・30・45・60・90・135・180・240・300・450・600A | 50~100% | By connecting an external regulator (sold separately) | Constant voltage, constant current, constant power, voltage squared |
Between power supply terminal and ground terminal 500V DC 20MΩ or more Between power supply terminal and control input terminal 500V DC 20MΩ or more |
20A: approx. 9kg, 30/45A: approx. 12kg, 60/90A: approx. 16.5kg, 135/180/240/300A: approx. 36kg, 450/600A: approx. 36kg | -10~50℃, 90%RH or less (no condensation) | By built-in CT | 0~60%, 1~60sec | 200~220V, 220~240V, 380~400V, 400~440V AC 50/60Hz | Overcurrent detection (stops at 130% of rated current), fast-acting fuse | 1~10sec |
200~240V between power terminal and ground terminal 2000V AC for 1 minute 380~440V between power terminal and ground terminal 2500V AC for 1 minute |