Product
Console server SmartCS NS-2250 seriesHandling Company
Seiko Solutions Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | AC dual power supply model | Common | DC power model | Device led | Emissions | External dimensions | External expansion slot | Immunity 1 | Immunity 2 | LAN port | Maximum current consumption | Maximum power consumption | Number of serial ports | Operating environment | Other features | Port server function | Power specifications | Power supply | Safety standards | Security | Serial port configurable speed | Various operational support functions | Weight |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
NS-2250-16 |
Available upon quote |
AC100V power cable x2 Fallout prevention clamp x 2 |
USB memory (for saving settings) NS-354 DB9-RJ45 conversion adapter (for this device console) ethernet cable rack mount kit |
Connector for DC power cable connector jig |
Power LED, device status LED (4 lights), port LED |
VCCI class A FCC Part15, Subpart B Class A EN 55032:2012 Class A EN 61000-3-2:2014 EN 61000-3-3:2013 |
426 (W) × 262 (D) × 44 (H) mm | USB port |
EN 55024:2010 EN 61000-4-2:2009 EN 61000-4-3:2006+A1:2008+A2:2010 EN 61000-4-4:2012 |
EN 61000-4-5:2006 EN 61000-4-6:2009 EN 61000-4-8:2010 EN 61000-4-11:2004 |
10BASE-T/100BASE-TX/1,000Base-T×2 |
AC dual power supply model: AC 100 V: 0.32 A / AC 240 V: 0.18 A DC power model: 0.3A |
AC dual power supply model: 17W DC power model: 15W |
RJ45×16port | Temperature: 5℃~40℃, Humidity: 15~85% (no condensation) | Break safe function |
・Provides Telnet/SSH client access to serial port ・Various log acquisition and automatic transmission functions ・Time stamp can be added to the acquisition log |
AC power supply x 2 |
AC dual power supply model: AC100V~240V DC power model: DC-48V |
IEC 62368-1:2014 (2nd Edition) EN 62368-1:2014 + A11:2017 (2nd Edition) UL 62368-1:2014 (2nd Edition) |
SSHv2, RSA/DSA encryption key, access right control, external authentication (RADIUS/TACACS+) | 2,400, 4,800, 9,600, 19,200, 38,400, 57,600, 115,200 (bps) |
Connection status list display, log usage status display Version upgrade via syslog, SNTP, SNMP, Trap, FTP |
Approximately 3.4kg | |
NS-2250-16D |
Available upon quote |
AC100V power cable x2 Fallout prevention clamp x 2 |
USB memory (for saving settings) NS-354 DB9-RJ45 conversion adapter (for this device console) ethernet cable rack mount kit |
Connector for DC power cable connector jig |
Power LED, device status LED (4 lights), port LED |
VCCI class A FCC Part15, Subpart B Class A EN 55032:2012 Class A EN 61000-3-2:2014 EN 61000-3-3:2013 |
426 (W) × 262 (D) × 44 (H) mm | USB port |
EN 55024:2010 EN 61000-4-2:2009 EN 61000-4-3:2006+A1:2008+A2:2010 EN 61000-4-4:2012 |
EN 61000-4-5:2006 EN 61000-4-6:2009 EN 61000-4-8:2010 EN 61000-4-11:2004 |
10BASE-T/100BASE-TX/1,000Base-T×2 |
AC dual power supply model: AC 100 V: 0.32 A / AC 240 V: 0.18 A DC power model: 0.3A |
AC dual power supply model: 17W DC power model: 15W |
RJ45×16port | Temperature: 5℃~40℃, Humidity: 15~85% (no condensation) | Break safe function |
・Provides Telnet/SSH client access to serial port ・Various log acquisition and automatic transmission functions ・Time stamp can be added to the acquisition log |
DC power supply x 1 |
AC dual power supply model: AC100V~240V DC power model: DC-48V |
IEC 62368-1:2014 (2nd Edition) EN 62368-1:2014 + A11:2017 (2nd Edition) UL 62368-1:2014 (2nd Edition) |
SSHv2, RSA/DSA encryption key, access right control, external authentication (RADIUS/TACACS+) | 2,400, 4,800, 9,600, 19,200, 38,400, 57,600, 115,200 (bps) |
Connection status list display, log usage status display Version upgrade via syslog, SNTP, SNMP, Trap, FTP |
Approximately 3.4kg | |
NS-2250-32 |
Available upon quote |
AC100V power cable x2 Fallout prevention clamp x 2 |
USB memory (for saving settings) NS-354 DB9-RJ45 conversion adapter (for this device console) ethernet cable rack mount kit |
Connector for DC power cable connector jig |
Power LED, device status LED (4 lights), port LED |
VCCI class A FCC Part15, Subpart B Class A EN 55032:2012 Class A EN 61000-3-2:2014 EN 61000-3-3:2013 |
426 (W) × 262 (D) × 44 (H) mm | USB port |
EN 55024:2010 EN 61000-4-2:2009 EN 61000-4-3:2006+A1:2008+A2:2010 EN 61000-4-4:2012 |
EN 61000-4-5:2006 EN 61000-4-6:2009 EN 61000-4-8:2010 EN 61000-4-11:2004 |
10BASE-T/100BASE-TX/1,000Base-T×2 |
AC dual power supply model: AC 100 V: 0.32 A / AC 240 V: 0.18 A DC power model: 0.3A |
AC dual power supply model: 17W DC power model: 15W |
RJ45×32port | Temperature: 5℃~40℃, Humidity: 15~85% (no condensation) | Break safe function |
・Provides Telnet/SSH client access to serial port ・Various log acquisition and automatic transmission functions ・Time stamp can be added to the acquisition log |
AC power supply x 2 |
AC dual power supply model: AC100V~240V DC power model: DC-48V |
IEC 62368-1:2014 (2nd Edition) EN 62368-1:2014 + A11:2017 (2nd Edition) UL 62368-1:2014 (2nd Edition) |
SSHv2, RSA/DSA encryption key, access right control, external authentication (RADIUS/TACACS+) | 2,400, 4,800, 9,600, 19,200, 38,400, 57,600, 115,200 (bps) |
Connection status list display, log usage status display Version upgrade via syslog, SNTP, SNMP, Trap, FTP |
Approximately 3.4kg | |
NS-2250-32D |
Available upon quote |
AC100V power cable x2 Fallout prevention clamp x 2 |
USB memory (for saving settings) NS-354 DB9-RJ45 conversion adapter (for this device console) ethernet cable rack mount kit |
Connector for DC power cable connector jig |
Power LED, device status LED (4 lights), port LED |
VCCI class A FCC Part15, Subpart B Class A EN 55032:2012 Class A EN 61000-3-2:2014 EN 61000-3-3:2013 |
426 (W) × 262 (D) × 44 (H) mm | USB port |
EN 55024:2010 EN 61000-4-2:2009 EN 61000-4-3:2006+A1:2008+A2:2010 EN 61000-4-4:2012 |
EN 61000-4-5:2006 EN 61000-4-6:2009 EN 61000-4-8:2010 EN 61000-4-11:2004 |
10BASE-T/100BASE-TX/1,000Base-T×2 |
AC dual power supply model: AC 100 V: 0.32 A / AC 240 V: 0.18 A DC power model: 0.3A |
AC dual power supply model: 17W DC power model: 15W |
RJ45×32port | Temperature: 5℃~40℃, Humidity: 15~85% (no condensation) | Break safe function |
・Provides Telnet/SSH client access to serial port ・Various log acquisition and automatic transmission functions ・Time stamp can be added to the acquisition log |
DC power supply x 1 |
AC dual power supply model: AC100V~240V DC power model: DC-48V |
IEC 62368-1:2014 (2nd Edition) EN 62368-1:2014 + A11:2017 (2nd Edition) UL 62368-1:2014 (2nd Edition) |
SSHv2, RSA/DSA encryption key, access right control, external authentication (RADIUS/TACACS+) | 2,400, 4,800, 9,600, 19,200, 38,400, 57,600, 115,200 (bps) |
Connection status list display, log usage status display Version upgrade via syslog, SNTP, SNMP, Trap, FTP |
Approximately 3.4kg | |
NS-2250-48 |
Available upon quote |
AC100V power cable x2 Fallout prevention clamp x 2 |
USB memory (for saving settings) NS-354 DB9-RJ45 conversion adapter (for this device console) ethernet cable rack mount kit |
Connector for DC power cable connector jig |
Power LED, device status LED (4 lights), port LED |
VCCI class A FCC Part15, Subpart B Class A EN 55032:2012 Class A EN 61000-3-2:2014 EN 61000-3-3:2013 |
426 (W) × 262 (D) × 44 (H) mm | USB port |
EN 55024:2010 EN 61000-4-2:2009 EN 61000-4-3:2006+A1:2008+A2:2010 EN 61000-4-4:2012 |
EN 61000-4-5:2006 EN 61000-4-6:2009 EN 61000-4-8:2010 EN 61000-4-11:2004 |
10BASE-T/100BASE-TX/1,000Base-T×2 |
AC dual power supply model: AC 100 V: 0.32 A / AC 240 V: 0.18 A DC power model: 0.3A |
AC dual power supply model: 17W DC power model: 15W |
RJ45×48port | Temperature: 5℃~40℃, Humidity: 15~85% (no condensation) | Break safe function |
・Provides Telnet/SSH client access to serial port ・Various log acquisition and automatic transmission functions ・Time stamp can be added to the acquisition log |
AC power supply x 2 |
AC dual power supply model: AC100V~240V DC power model: DC-48V |
IEC 62368-1:2014 (2nd Edition) EN 62368-1:2014 + A11:2017 (2nd Edition) UL 62368-1:2014 (2nd Edition) |
SSHv2, RSA/DSA encryption key, access right control, external authentication (RADIUS/TACACS+) | 2,400, 4,800, 9,600, 19,200, 38,400, 57,600, 115,200 (bps) |
Connection status list display, log usage status display Version upgrade via syslog, SNTP, SNMP, Trap, FTP |
Approximately 3.4kg | |
NS-2250-48D |
Available upon quote |
AC100V power cable x2 Fallout prevention clamp x 2 |
USB memory (for saving settings) NS-354 DB9-RJ45 conversion adapter (for this device console) ethernet cable rack mount kit |
Connector for DC power cable connector jig |
Power LED, device status LED (4 lights), port LED |
VCCI class A FCC Part15, Subpart B Class A EN 55032:2012 Class A EN 61000-3-2:2014 EN 61000-3-3:2013 |
426 (W) × 262 (D) × 44 (H) mm | USB port |
EN 55024:2010 EN 61000-4-2:2009 EN 61000-4-3:2006+A1:2008+A2:2010 EN 61000-4-4:2012 |
EN 61000-4-5:2006 EN 61000-4-6:2009 EN 61000-4-8:2010 EN 61000-4-11:2004 |
10BASE-T/100BASE-TX/1,000Base-T×2 |
AC dual power supply model: AC 100 V: 0.32 A / AC 240 V: 0.18 A DC power model: 0.3A |
AC dual power supply model: 17W DC power model: 15W |
RJ45×48port | Temperature: 5℃~40℃, Humidity: 15~85% (no condensation) | Break safe function |
・Provides Telnet/SSH client access to serial port ・Various log acquisition and automatic transmission functions ・Time stamp can be added to the acquisition log |
DC power supply x 1 |
AC dual power supply model: AC100V~240V DC power model: DC-48V |
IEC 62368-1:2014 (2nd Edition) EN 62368-1:2014 + A11:2017 (2nd Edition) UL 62368-1:2014 (2nd Edition) |
SSHv2, RSA/DSA encryption key, access right control, external authentication (RADIUS/TACACS+) | 2,400, 4,800, 9,600, 19,200, 38,400, 57,600, 115,200 (bps) |
Connection status list display, log usage status display Version upgrade via syslog, SNTP, SNMP, Trap, FTP |
Approximately 3.4kg |
Click on the part number for more information about each product