All Categories
History
Price (excluding tax)
High accuracy ⾚ External non -contact temperature sensor OPTRIS®CT1M/2m feature ・ Measurement temperature range: 250 to 2200 ° C -The detected wave length of 1.0 μm and 1.6 μm can measure the temperature of objects such as glossy genus, ⼆ ⾦ ⾦ genus, ⾦ ⾦ oxide, and ceramic material over the glass. ・ The shortwave bandwidth 1.0 μm and 1.6 μm can be measured by mimic the radiation rate error at the time of measurement. ・ The ⼩ type size (D) 14x (L) 28mm sensing head is suitable for any mounting location, and can be used up to 125 ° C without cooling. ・ The measured temperature range is 250-2200 ° C, the spot size is 1.8 mm, and the response time is 1 ms.
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Alarm outing
Cable length
Detected wave
Digital output (optional)
Impact resistance
Operating environment temperature electronics section
Operating environment temperature sensing head
Optical resolution (90%energy)
Outlation impedance
Permeability
Radiation rate/gain
Relative humidity
Relay (optional)
Reproduction (environmental temperature 23 ± 5 ℃)
Response time
Saving temperature electronics section
Saving temperature sensing head
Signal processing (Each parameter can be adjusted with programming keys or software)
System measurement accuracy (environment temperature 23 ± 5 ℃)
Temperature coefficient
Temperature decomposition ability
Vibration resistance
Weight (electronics section)
Weight (sensing head)
power supply
software
water resistant
Power consumption
input
Part Number
Optct1m / 2mHandling Company
SSS CorporationCategories
Image | Price (excluding tax) | Alarm outing | Cable length | Detected wave | Digital output (optional) | Impact resistance | Operating environment temperature electronics section | Operating environment temperature sensing head | Optical resolution (90%energy) | Outlation impedance | Permeability | Power consumption | Radiation rate/gain | Relative humidity | Relay (optional) | Reproduction (environmental temperature 23 ± 5 ℃) | Response time | Saving temperature electronics section | Saving temperature sensing head | Signal processing (Each parameter can be adjusted with programming keys or software) | System measurement accuracy (environment temperature 23 ± 5 ℃) | Temperature decomposition ability | Vibration resistance | Weight (electronics section) | Weight (sensing head) | input | power supply | software | water resistant |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | 24V/50mA (open collector) | 3m (standard), 8m, 15m | 1.0μm (1m)/1.6 μm (2m) | USB, RS232, RS485, Can, Professional DP, Ethernet | IEC68-27: 50g, 11ms (regardless of angle) | 0 to 85 ° C | -20-100 ° C (1m) -20-125 ° C (2m) | 40: 1 (2.7mmф110mm) 1ml/2ml75: 1 (1.5mmф110mm) 1MH/1MH1/2MH1 | MAMAX, 500Ω (8-36VDC) mvmin.100kΩ load impedance serumocapul 20Ω | 0.100-1.100 (Adjustable with programming keys or software) | Up to 100mA | 0.100-1.100 (Adjustable with programming keys or software) | 10-95 % (without condensation) | 2x60VDC/42vaceff/0.4a; | ± 0.1%+1 ° C for reading values | 1ms | -40-85 ℃ | 40-100 ° C (1m) -40-125 ° C (2m) | Peak Hold Valley Hold Aberage, Slacod and Hysteresis Expansion Hold Function | ± 0.3%+2 ° C for reading values | 0.1k | IEC68-2-6: 3G, 11-200Hz (regardless of angle) | 420g | 40g | External radioactivity adjustment, surrounding temperature correction, trigger program function (hold function reset) | 8-36VDC | OPTRISCOMPACTCONNECT | IP65 (NEMA-4) |
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.