AT-H60K-1Handling Company
Otowa Electric Industry Co., Ltd.| Image | Price (excluding tax) | Abnormality judgment () | Environmental conditions () | Mass () | Maximum output voltage () | Measurement () | Measuring range () | Output accuracy () | Output polarity () | Power consumption () | Power supply () |
|---|---|---|---|---|---|---|---|---|---|---|---|
|
Available upon quote | Overvoltage abnormality: When reaching 95% of the maximum output voltage Overcurrent abnormality: When the output voltage is less than 1kV and the current flows more than 0.7mA | Temperature: 0°C~+50°C Humidity: 0~80% (no condensation) | Approximately 20kg | DC60kV | DC operation start voltage (DC V1mA) | 5~95% of maximum output voltage | Voltage: F.S. within ±2% Current: within ±30μA | Positive electrode | 250W or less | AC200-240V (50/60Hz) |