All Categories
History
Price (excluding tax)
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Charging current
Charging range
Communication
Continuous output
Efficiency
Float charge
Input side current
Input side protection low voltage
Input side protection overvoltage
Input voltage range
Instantaneous output
Maximum charging power
Maximum output
No-load standby power
Operating humidity range
Operating temperature range
Output frequency
Output side protection
Output voltage fluctuation value
Output waveform
Overload
Parc charge
Rated input voltage
Remote control
Reverse connection
Side rated output voltage
Storage temperature range
Temperature compensation
UPS mode
When power is OFF
Part Number
NTN-5K-148Handling Company
Earth Power Co., Ltd.Categories
Image | Price (excluding tax) | Charging current | Charging range | Communication | Continuous output | Efficiency | Float charge | Input side current | Input side protection low voltage | Input side protection overvoltage | Input voltage range | Instantaneous output | Maximum charging power | Maximum output | No-load standby power | Operating humidity range | Operating temperature range | Output frequency | Output side protection | Output voltage fluctuation value | Output waveform | Overload | Parc charge | Rated input voltage | Remote control | Reverse connection | Side rated output voltage | Storage temperature range | Temperature compensation | UPS mode | When power is OFF |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | 60A | DC42.0V~DC60.0V | MODBus-RTU (RS-485) /CANBus | 4,000W | 91.00% | DC55.2V | 100A | Alarm DC44.0V and DC1.0V Cutoff DC40.0V and DC1.0V Restart DC50.0V and DC1.0V | Overvoltage alarm DC62.0V and DC1.0V Overvoltage cutoff DC66.0V and DC1.0V Restart DC60.0V and DC1.0V | DC40.0V~DC66.0V | 8,000W | 3,600W | (10sec) 6,000W (180sec) 4,600W | Power save OFF: 1.4A Power save ON: When the side standby power connection load capacity is 10W or less, Automatically shifts to power saving mode <25W | 20%~90%RH (No condensation) | -30~70℃ | At the time of shipment: 60-shi 0.1Hz (50-shi 0.1Hz/60-shi 0.1Hz switchable) | Overtemperature After overvoltage protection is detected and operation stops, automatic recovery occurs when temperature is resolved. Short circuit Disconnect the connection and turn the power back on to recover. circuit breaker 50A | 3.0% (input side: rated output value at DC25.0V/DC50.0V) | Sine wave (distortion rate: 3.0% or less) | 180 seconds 105~115% of load capacity 115~150% of load capacity for 10 seconds | DC57.6V | DC48V | Output side ON/OFF remote terminal (RC terminal) | Error After disconnecting all connections Recovers when power is turned on again | Factory shipped AC110V (AC100V/AC115V/AC120V switchable) | -30~+70℃ | External temperature sensor | AC input range AC100V AC110V AC115V AC120V 16% Frequency range 45Hz~65Hz Switching time Inverter mode UPS mode Switching in 001 seconds | ≦1mA |
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.