All Categories
History
Price (excluding tax)
Response Rate
100.0%
Response Time
8.9hours
Fast Response
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Connection size (LCS-0.5CCM/LCR-1LPM)
Controllable flow rate
Dimensions (LCS-0.5CCM/LCR-1LPM)
Flow range ratio
Flow rate accuracy
Flow rate setting
Fluid
Fluid temperature
Maximum pressure
Operating range
Operating temperature
Pressure loss at F.S. flow rate
Repeatability
Response speed
Span shift
Zero shift
Part Number
LCR/LCRS seriesProduct
Liquid flow controllerHandling Company
Japan Star Techno Co., Ltd.Categories
Image | Price (excluding tax) | Connection size (LCS-0.5CCM/LCR-1LPM) | Controllable flow rate | Dimensions (LCS-0.5CCM/LCR-1LPM) | Flow range ratio | Flow rate accuracy | Flow rate setting | Fluid | Fluid temperature | Maximum pressure | Operating range | Operating temperature | Pressure loss at F.S. flow rate | Repeatability | Response speed | Span shift | Zero shift |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | 1/4" NPT female thread | 102.4% F.S. | H149.30 x W194.31 x D57.15 | 50:1 | ±2% F.S. | Display switch/analog input/communication | Pure water with conductivity of 400ppm or less or methanol, isopropanol, ethanol, ammonia, Dimethyl ether, isopentane, thiophene, isooctane, heptane, acetone *Calibrate with one of these types | -10~60℃ (not frozen) | 100PSIG (689kPa) | 2~100% F.S. | -10~60℃ (not frozen) | 27.58kPaD | ±2% F.S. | 100ms | 0.02% F.S./℃/Atm | 0.02% F.S./℃/Atm |
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.
Response Rate
100.0%
Response Time
8.9hrs