All Categories
History
Price (excluding tax)
Relatively Fast Response
You can search for other models from each index. The displayed value is the value of the currently selected part number.
AC input Number of phases and wires
AC input allowable frequency fluctuation range
AC input allowable voltage fluctuation range
AC input rated frequency
AC input rated voltage
AC output Number of phases and wires
AC output load power factor fluctuation range
AC output rated capacity
AC output rated frequency
AC output rated load power factor
AC output rated voltage
AC output voltage adjustment range
Circuit method Equipped with bypass circuit
Circuit method Main circuit control method
Circuit method Power supply method
Circuit method Storage battery supply method
DC input Number of storage battery cells
DC input allowable voltage fluctuation range
DC input nominal voltage
Output performance External synchronization frequency range
Output performance Frequency accuracy (internal synchronization)
Output performance Instantaneous voltage fluctuation Parallel input/analysis
Output performance Instantaneous voltage fluctuation Power outage/power restoration
Output performance Instantaneous voltage fluctuation Sudden load change 0⇔100%
Output performance Instantaneous voltage fluctuation recovery time
Output performance Output voltage accuracy
Output performance Overcurrent capability Bypass circuit
Output performance Overcurrent capability Inverter
Output performance Voltage waveform distortion factor Linear load
Output performance Voltage waveform distortion rate Nonlinear load
Part Number
HIVERTER-UP201i-1.6Handling Company
Kyushu Kiden Co., Ltd.Categories
Image | Price (excluding tax) | AC input Number of phases and wires | AC input allowable frequency fluctuation range | AC input allowable voltage fluctuation range | AC input rated frequency | AC input rated voltage | AC output Number of phases and wires | AC output load power factor fluctuation range | AC output rated capacity | AC output rated frequency | AC output rated load power factor | AC output rated voltage | AC output voltage adjustment range | Circuit method Equipped with bypass circuit | Circuit method Main circuit control method | Circuit method Power supply method | Circuit method Storage battery supply method | DC input Number of storage battery cells | DC input allowable voltage fluctuation range | DC input nominal voltage | Output performance External synchronization frequency range | Output performance Frequency accuracy (internal synchronization) | Output performance Instantaneous voltage fluctuation Parallel input/analysis | Output performance Instantaneous voltage fluctuation Power outage/power restoration | Output performance Instantaneous voltage fluctuation Sudden load change 0⇔100% | Output performance Instantaneous voltage fluctuation recovery time | Output performance Output voltage accuracy | Output performance Overcurrent capability Bypass circuit | Output performance Overcurrent capability Inverter | Output performance Voltage waveform distortion factor Linear load | Output performance Voltage waveform distortion rate Nonlinear load |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | Three phase three wire | Within ±5% | Within ±10% | 50Hz/60Hz | 415V | Three phase three wire | 0.7 delay~1.0 | 160kVA | 50Hz/60Hz | 0.9 lag 0.95 delay (optional) | 415V | Within ±5% | Built-in bypass circuit and maintenance bypass circuit | PWM (pulse width modulation control) method | Constant inverter power supply system | Individual storage battery method | 246 cells ~ 272 cells | 393V~607V | 492V~544V | Within ±1.0% | Within ±0.1% | Within ±5.0% | Within ±2.0% | Within ±5.0% | Within 50ms | Within ±1.0% | 1,000% - 1 cycle | 125% - 10 minutes 150% - 1 minute 200% - 0.1 seconds | Within 2.5% | Within 5.0% |
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.
Response Rate
100.0%
Response Time
29.3hrs
Company Review
5.0